The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives

نویسندگان

  • Grace E Dunbar
  • Bailey Yuguan Shen
  • Ahmad A Aref
چکیده

Intraocular pressure, a major modifiable risk factor for glaucoma, has been shown to fluctuate throughout the day in patients with glaucoma. The detection and measurement of this fluctuation may help guide the clinical management of glaucomatous individuals. The Sensimed Triggerfish contact lens sensor (CLS), which has recently gained approval for marketing in the USA, is designed to detect intraocular pressure-related changes in an eye over a 24-hour period. This review will provide an overview of the Triggerfish CLS, as well as summarize current clinical data pertaining to the device. Overall, the current evidence suggests that the Triggerfish CLS is safe and well tolerated, and provides reproducible results. One challenge of using the Triggerfish CLS is that it may only provide data on relative changes in intraocular pressure rather than absolute intraocular pressure. In addition, its validity at estimating intraocular pressure compared to other methods is still controversial. Despite these limitations, recent studies suggest a myriad of potential indications for the Triggerfish CLS, including predicting glaucomatous progression and predicting efficacy of glaucoma treatment. With further research, the Triggerfish CLS may become a useful tool for eye care practitioners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma.

OBJECTIVE To examine the safety, tolerability, and reproducibility of intraocular pressure (IOP) patterns during repeated continuous 24-hour IOP monitoring with a contact lens sensor. METHODS Forty patients suspected of having glaucoma(n=21) or with established glaucoma (n=19) were studied.Patients participated in two 24-hour IOP monitoring sessions (S1 and S2) at a 1-week interval (SENSIMED ...

متن کامل

Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.

PURPOSE To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sen...

متن کامل

The Fluctuation of Intraocular Pressure Measured by a Contact Lens Sensor in Normal-Tension Glaucoma Patients and Nonglaucoma Subjects.

PURPOSE We compared the fluctuation of intraocular pressure (IOP) in normal-tension glaucoma (NTG) patients and individuals with nonglaucoma eyes. We obtained continuous IOP values using a SENSIMED Triggerfish contact lens sensor. MATERIALS AND METHODS The eyes of 12 nonglaucoma subjects and 14 NTG patients were examined. In all 26 subjects, the IOP fluctuation was measured continuously for 2...

متن کامل

Assessing Efficacy of Canaloplasty Using Continuous 24-Hour Monitoring of Ocular Dimensional Changes.

PURPOSE We investigated whether 24-hour monitoring of corneoscleral limbus area (CSLA) with the Sensimed Triggerfish contact lens sensor (CLS) can be used clinically to assess midterm efficacy of canaloplasty and to assess the relationships of CSLA changes with the heart rhythm. METHODS Ten eyes of 10 patients, with POAG, which were qualified either to canaloplasty or canaloplasty and phacoem...

متن کامل

Efficacy of a Contact Lens Sensor for Monitoring 24-H Intraocular Pressure Related Patterns

PURPOSE To study performance of a contact lens sensor (CLS) for 24-hour monitoring of IOP-related short-term patterns and compare with IOP obtained by pneumatonometry. METHODS Prospective clinical trial. Thirty-one healthy volunteers and 2 glaucoma patients were housed for 24 hours in a sleep laboratory. One randomly selected eye was fitted with a CLS (Triggerfish, Sensimed, Switzerland), whi...

متن کامل

ذخیره در منابع من