Comparison of direct intubation and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T.) for endotracheal intubation during cardiopulmonary resuscitation. Randomized manikin study.

نویسندگان

  • Andrzej Kurowski
  • Łukasz Szarpak
  • Piotr Zaśko
  • Łukasz Bogdański
  • Zenon Truszewski
چکیده

BACKGROUND Airway control is a potentially lifesaving procedure, but intubation by direct laryngoscopy may be difficult. The aim of this study was to assess the success rate of tracheal intubation using the Macintosh laryngoscope and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T) device. METHODS This is a randomised cross-over study involving 120 paramedics utilising the Macintosh laryngoscope and S.A.L.T. during simulated cardiopulmonary resuscitation (CPR) on a manikin. We compared times to successful intubation and intubation success rates for intubation using Macintosh and S.A.L.T. performed by paramedics, during CPR with and without chest compression. RESULTS Mean intubation times for conventional laryngoscopic intubation and S.A.L.T. without chest compressions were 31.52 ± 7.23 s and 17.97 ± 5.33 s, respectively (P < 0.001). CONCLUSIONS Intubation via the S.A.L.T. was more successful than conventional laryngoscopic intubation, regardless of whether chest compressions were interrupted or not.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of airway management associated hands-off time during cardiopulmonary resuscitation: a randomised manikin follow-up study

INTRODUCTION Airway management is an important component of cardiopulmonary resuscitation (CPR). Recent guidelines recommend keeping any interruptions of chest compressions as short as possible and not lasting more than 10 seconds. Endotracheal intubation seems to be the ideal method for establishing a secure airway by experienced providers, but emergency medical technicians (EMT) often lack tr...

متن کامل

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study

INTRODUCTION Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been...

متن کامل

Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians?

UNLABELLED The aim of this study was to assess the performance of the ETView VivaSight SL (ETView) single-lumen airway tube with an integrated high-resolution imaging camera in a manikin-simulated cardiopulmonary resuscitation scenario with and without chest compression. This was a randomized crossover manikin trial. Following a brief training session, 107 volunteer novice physicians who were i...

متن کامل

Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial

BACKGROUND Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation. We compared the utility of the Pentax-AWS Airwayscope (AWS) with the Glidescope (GS) during chest compressions on an infant manikin. METHODS Twenty-four anesthesiologists with more than two years of experience p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anaesthesiology intensive therapy

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2015