Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.

نویسنده

  • David F Chang
چکیده

PURPOSE To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs. SETTING Private practice, Los Altos, California, USA. METHODS One hundred consecutive eyes with an AcrySof SN60T(3, 4, or 5) toric IOL were compared with a consecutive series of 90 AA4203 (TL or TF) toric IOLs. The same surgeon performed all IOL implantations using an identical surgical technique. In addition to deviation from the desired axis, the change in refractive cylinder was measured 1 month postoperatively. RESULTS Although surgery was performed during different time periods, the 2 populations had a similar distribution of patient age, axial lengths, and spherical IOL powers. In the AcrySof SN60T group, 90%, 99%, and 100% of the IOLs were aligned at or within 5, 10, and 15 degrees, respectively, of the desired axis and in the AA4203 group, 70%, 90%, and 97%, respectively. The mean IOL rotation was 5.56 degrees +/- 8.49 (SD) in the AA4203 group and 3.35 +/- 3.41 degrees in the AcrySof SN60T group (P = .0232). One AcrySof SN60T IOL (1%) and 8 AA4203 IOLs (8.9%) were 15 degrees or more off axis (P = .01). No AcrySof SN60T IOL and 3.3% of AA4203 IOLs required surgical repositioning. CONCLUSIONS Both toric IOLs had good rotational stability and were effective in reducing preexisting corneal astigmatism. Based on the mean axis deviation and the number of IOLs rotating 15 degrees or more, the AcrySof SN60T toric IOL showed statistically better rotational stability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lens.

PURPOSE To compare the rotational stability and posterior capsule opacification (PCO) rate in eyes with a 1-piece or 3-piece acrylic intraocular lens (IOL). SETTING Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. DESIGN Prospective randomized masked clinical trial. METHODS Patients with age-related cataract received a plate-haptic acrylic IOL (Acri.Smart 46S) i...

متن کامل

Stability of a three-piece silicone intraocular lens implanted in the capsular bag

odern cataract surgery aims not only to remove lens opacities but also to achieve correction of any refractive error. In addition to restoration of uncorrected visual acuity, correction of preexisting astigmatism is also important, and treatment options for this purpose include corneal limbal relaxing incisions, excimer laser photoablation and toric intraocular lens (IOL) implantation. Shimizu ...

متن کامل

Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases.

PURPOSE To determine whether rotational stability is improved with the longer Staar toric intraocular lens (IOL). SETTING A private practice, Los Altos, California, USA. METHODS Staar Surgical manufactures toric plate-haptic IOLs under +24.0 diopters (D) in 2 lengths. Fifty consecutive eyes requiring toric IOL spherical powers less than +24.0 D received the longer toric IOL (TL; 11.2 mm) us...

متن کامل

Suture Fixation Technique for a Single-piece Foldable Closed-loop Intraocular Lens

PURPOSE We describe a suture fixation technique for a single-piece foldable acrylic closed-loop intraocular lens (IOL) (C-flex, Rayner). METHODS In our experimental model analyzing the stability of acrylic haptics, we confirmed that the IOL could be in counterpoise without tilt using only a two-point fixation. This new surgical technique was performed in seven patients. RESULTS The unique h...

متن کامل

Effect of number and position of intraocular lens haptics on anterior capsule contraction: a randomized, prospective trial

BACKGROUND The present study aimed to evaluate the degree of anterior capsule contraction (capsulorhexis contraction) with three different single-piece, hydrophilic acrylic intraocular lenses (IOLs). METHODS Patients were prospectively randomized to be implanted with one of three types of IOLs during cataract surgery: the Ophtec Precizon (IOL A), the Lucid Korea Microflex (IOL B), and the Car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 34 11  شماره 

صفحات  -