Perineal Post Padding Technique to Improve Hip Distraction in Tall Patients.

نویسندگان

  • Benjamin D Kuhns
  • Brandon J Erickson
  • Leah R Bressler
  • Sara M Sarmast
  • Shane J Nho
چکیده

Hip distraction is necessary for safe arthroscopic entry into the hip joint. Achieving sufficient distraction is difficult in exceedingly tall patients (>190.5 cm) because of size limitations of currently available hip distraction systems. Inadequate distraction can delay the surgical procedure and potentially lead to complications. By repurposing a foam head-positioning block, we report a safe and inexpensive positioning technique for extending the traction distance for tall patients by 2 inches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peroneal padding: an alternative to a peroneal post in hip arthroscopy.

Hip arthroscopy is commonly used both to diagnose and treat different underlying hip conditions. It may be performed either by a supine or lateral approach. A peroneal post is commonly used with a fracture table in both the supine and lateral positions to provide lateralization and traction of the femur. Adequate distraction of the hip joint may be difficult without the peroneal post. We achiev...

متن کامل

Hip arthroscopy distraction without the use of a perineal post: prospective study.

Hip arthroscopy is being used with increasing frequency as the understanding of arthroscopic management of groin pain improves. To access the hip joint arthroscopically, traction must be placed on the leg. In most cases, countertraction is provided with a padded post in the groin. Complications of traction are often attributed to the post and include perineal or pudendal neuropraxias and skin c...

متن کامل

Can three-phase skeletal scintigraphy predict the outcome and determine the timing of removal of bone distracters in avascular necrosis of femur using a novel corticostomy technique?

Introduction: 99mTc-Methylene diphosphonate (99mTc-MDP) three phase bone scintigraphy (TPS) is beneficial to evaluate the success of femoral head revascularization using novel distraction osteogenesis techniques with bone muscle pedicle grafts. This pilot study was undertaken to evaluate the feasibility and utility of 99mTc-MDP three phase bone ...

متن کامل

Pelvic Support Osteotomy; Salvage Procedure in Chronically Dislocated Hips Case Report: Technical Note on the On-lay Bone Positioning of a Lengthening Nail and Review of the Literature

BACKGROUND Young patients with a acquired dislocation of the hip with concomitant shortening of the lower limb is a difficult diagnostic problem with few definite treatment options. METHODS We used the technique, originally described by Ilizarov, with a double femur osteotomy and lengthening the femur. Lengthening was done with a sub muscular placed on-lay femur distraction rod. Distraction o...

متن کامل

A novel non-invasive hip traction technique for hip arthroscopy in the below-knee amputation (BKA) patient

Prolonged sitting and mobilizing from a seated position are known to exacerbate the symptoms in patients with hip pathology. For patients who lack mobility and require extended periods of time in seated positions, such as amputees, the symptoms of femeroacetabular impingement can be debilitating and limit their ability to operate a wheelchair, use a prosthetic limb or complete activities of dai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy techniques

دوره 4 6  شماره 

صفحات  -