[Rest delayed images on 99mTc-MIBI myocardial SPECT as a noninvasive screen for the diagnosis of vasospastic angina pectoris].
نویسندگان
چکیده
Diagnostic usefulness of 99mTc-MIBI myocardial SPECT at rest was examined in 39 cases of coronary vasospastic angina pectoris who were diagnosed by a positive reaction to ergonovine provocation. SPECT was performed 45 minutes (early image) and 3 hours (delayed image) after the intravenous injection of approximately 600 MBq of MIBI. Decrease in accumulation was ranked by four defect scores (0: normal; 1: slight decrease; 2: moderate decrease; 3: severe decrease) and the total defect score was evaluated semiquantitatively. The washout rate between the normal area and the spasm area was also evaluated quantitatively using bull's eye. As a result, 15 cases (15/39; 38.4%) showed decreased accumulation in the early image and 27 cases (27/39; 69.2%) showed decreased accumulation in the delayed image. All of the cases which showed decreased accumulation in the early image had decreased accumulation in the delayed image as well. In 6 cases (6/34; 17.6%) showed ST wave changes during exercise ECG and 16 cases (16/34: 47%) showed decreased accumulation in the exercise myocardial SPECT. The washout rate of MIBI in the decreased accumulation area was significantly higher than that of the normal area. Of 32 ergonovine induced vasospastic area, 23 areas (72%) exhibited decreased accumulation in the delayed image for the same area. Decreased accumulation in the delayed image in MIBI was due to the enhanced washout, which, in turn, indicated declined retention of MIBI by mitochondrial membrane. In coronary vasospastic angina pectoris, spasm induced ischemia was thought to have an effect on the mitochondria. This study suggested that even with a normal exercise ECG and exercise myocardial SPECT, there's a strong possibility of coronary vasospastic angina pectoris if a decreased accumulation was found in the delayed image in the MIBI myocardial SPECT at rest. Hence, in diagnosing coronary vasospastic angina pectoris, the delayed image in the MIBI myocardial SPECT at rest was believed to be useful.
منابع مشابه
[Clinical usefulness of delayed exercise images on 99mTc-Tetrofosmin myocardial SPECT in the diagnosis of vasospastic angina pectoris].
This study was designed to evaluate the clinical usefulness of delayed exercise images in 99mTc-tetrofosmin (TF) myocardial SPECT in the diagnosis of vasospastic angina pectoris. We studied 30 patients with vasospastic angina, 10 of 30 patients (group A) had both effort and rest angina, 20 of 30 patients (group B) had rest angina. A 370 MBq of TF was intravenously injected at peak exercise, and...
متن کاملClinical implication of reverse redistribution on 99mTc-sestamibi images for evaluating ischemic heart disease.
OBJECTIVE The purpose of this study was to clarify the usefulness of 99mTc-sestamibi (MIBI) delayed imaging in the assessment of the severity of myocardial ischemia in patients with coronary artery stenosis. METHODS Forty-three angina pectoris with coronary stenosis of greater than 75% were enrolled in this study. Myocardial perfusion SPECT images were obtained 1 and 6 hours after an intraven...
متن کاملThe value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]
Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...
متن کاملQuantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.
We tested the hypothesis that 99mTc 2-methoxy-isobutyl-isonitrile (99mTc MIBI), a new radiopharmaceutical for myocardial perfusion imaging, provides accurate noninvasive detection of coronary artery disease (CAD). Imaging in patients after exercise and at rest with 99mTc MIBI was compared with imaging after exercise and redistribution with 201Tl in 12 normal subjects and 38 patients with angiog...
متن کاملTwo phase imaging of 99mTc-SESTAMIBI and 123I-BMIPP for patients with angina pectoris.
We saw three cases of angina pectoris in which 99mTc-SESTAMIBI delayed images at rest were useful in diagnosing ischemia risk areas. These findings indicated that delayed 99mTc-SESTAMIBI images may be more sensitive to slight ischemia than 123I-BMIPP images, and suggested that imaging with 99mTc-SESTAMIBI twice at rest may be more effective. The addition of 123I-BMIPP SPECT was considered to be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kaku igaku. The Japanese journal of nuclear medicine
دوره 39 2 شماره
صفحات -
تاریخ انتشار 2002