In vitro comparison of three techniques for ventriculo-aortic junction annuloplasty.

نویسندگان

  • Laurent de Kerchove
  • Riccardo Vismara
  • Andrea Mangini
  • Gianfranco Beniamino Fiore
  • Joel Price
  • Philippe Noirhomme
  • Carlo Antona
  • Gebrine El Khoury
چکیده

OBJECTIVES In aortic valve repair, reduction and stabilization of the ventriculo-aortic junction (VAJ) is generally recommended. In this in vitro study, we compare three techniques of annuloplasty: the subcommissural annuloplasty (SCA), the internal ring (IR) and the external ring (ER) annuloplasty. METHODS Ten fresh porcine aortic valve preparations were tested in a pulsatile mock loop. Each sample was tested untreated (baseline: B). The annuloplasty techniques were then performed successively in each sample. Each technique was tested, then removed and the following technique performed. SCA was applied at 50% of interleaflet triangle height; the ER and IR were applied with a moderate reduction (15-20%) of the VAJ. Hydrodynamic, video and echographic parameters were collected. Flow rate and arterial pressure were maintained consistently between groups. RESULTS Effective orifice area decreased significantly with each annuloplasty technique compared with baseline (P < 0.001). Mean transvalvular pressure drop was significantly higher in the ER and IR vs SCA (P = 0.007). Annuloplasty reduced valve opening and closing time in comparison to baseline. Echocardiography confirmed that the VAJ experienced a greater reduction with the ER and IR vs SCA. A narrowing of the lower third of the sinuses of Valsalva was observed after the ER, and subvalvular narrowing was observed after the IR. Valve coaptation increased with all annuloplasty techniques. CONCLUSIONS The three annuloplasty techniques examined demonstrated differential effects on aortic valve function and root morphology. The ER and IR have greater potential to reduce VAJ diameter in comparison to SCA. The IR induced a subvalvular remodelling of the VAJ, whereas the ER induced a paravalvular remodelling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomy and pathophysiology of the ventriculo-aortic junction: implication in aortic valve repair surgery.

To understand the different mechanisms of aortic regurgitation (AR), the aortic valve needs to be considered as a functional unit composed of three structures: (I) the functional aortic annulus (FAA), comprising of the ventriculo-aortic junction (VAJ) and the sino-tubular junction (STJ) (Figure 1); (II) the leaflets with their attachment; and (III) the three sinuses of Valsalva. The different m...

متن کامل

Aortic annuloplasty: a new aspect of aortic valve repair.

study because this is the technique that has been the most used in clinical practice for ventriculo-aortic junction reduction and stabilization. Of course, it has an effect on valve coaptation. It increased the coaptation by plications, or if you prefer, by closing the subcommissural triangle. This portion of the aortic root is just above what we considered to be the ventriculo-aortic junction,...

متن کامل

Effect of annulus dimension and annuloplasty on bicuspid aortic valve repair.

OBJECTIVES We have recently shown that valve sparing reimplantation (VSR) improves the durability of bicuspid aortic valve repair in comparison with subcommissural annuloplasty. The aim of this study was to assess the degree of annular reduction provided by these techniques and to correlate these findings with repair durability. METHODS From 1995 to 2010, 161 patients underwent bicuspid valve...

متن کامل

An intra-annular 'hemispherical' annuloplasty frame for aortic valve repair.

BACKGROUND AND AIM OF THE STUDY A 'Hemispherical' model of aortic valve geometry was developed in which normal human cadaveric aortic valve leaflets could be represented as three hemispheres nested within a cylindrical aorta. By mathematically describing the junction between the leaflets and aorta, the normal three-dimensional annular geometry of the aortic valve could be defined. In this study...

متن کامل

Impact of aortic annular geometry on aortic valve insufficiency: Insights from a preclinical, ex vivo, porcine model.

OBJECTIVES We sought to create a model of aortic insufficiency in a left heart simulator combined with 3-dimensional echocardiography and finite element modeling of the aortic valve. We examined the effects of aortic root geometry alteration on aortic insufficiency. METHODS Porcine aortic roots were analyzed on a left heart simulator before (control, n = 8) and after intervention (n = 8). Int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 41 5  شماره 

صفحات  -

تاریخ انتشار 2012