Endoscopic radial artery harvesting: results of first 300 patients.

نویسندگان

  • Mark W Connolly
  • Lisa D Torrillo
  • Michael J Stauder
  • Nilesh U Patel
  • John C McCabe
  • Didier F Loulmet
  • Valavanur A Subramanian
چکیده

BACKGROUND With the expanded use of the radial artery as a bypass conduit in patients undergoing coronary artery bypass grafting, an endoscopic radial artery harvesting method was used to improve esthetics and patient acceptance, and possibly, to decrease hand neurologic complications. METHODS After informed consent and confirmation of adequate ulnar collateral blood flow, 300 consecutive patients undergoing coronary artery bypass grafting had their nondominant radial artery endoscopically removed through a small 3-cm incision just proximal to the radial styloid prominence. Standard endoscopic vein equipment (30-degree 5-mm endoscope, subcutaneous retractor, and vessel dissector) with ultrasonic harmonic coagulating shears were used. After radial artery isolation, the radial artery was proximally clipped and transected 1 to 2 cm distal to the visualized ulnar artery origin to the inferior end of the wrist incision. RESULTS The mean age was 62.2 years; 23% of the patients were women, 39% had diabetes mellitus, and 28% had peripheral vascular disease. All 300 endoscopic radial arteries were grossly acceptable and used for grafting. Early in the series, 29 patients (9.7%) required a second 3-cm incision proximally for vascular control. Only one wrist incision was required at the last 200 cases. The conduit length varied between 18 and 24 cm. Occurring early in the series, hospital complications were two tunnel hematomas requiring drainage and one brachial artery clipping repaired primarily without sequela. At 30 days postoperative follow-up, 5 patients (1.6%) had been treated with oral antibiotics for incisional cellulitis and 26 patients (8.7%) had objective dorsal thenar sensory numbness. No ischemic hand complication, perioperative myocardial infarction, reintervention in radial artery graft distribution, or numbness in the lateral forearm occurred. All patients expressed marked satisfaction with the small incision and cosmetic result. CONCLUSIONS In our initial experience, endoscopic radial artery harvesting can be performed safely, with minor, infrequent complications. A full-length radial artery conduit can be obtained with improved esthetics and patient satisfaction and acceptance. Late dorsal thenar paresthesias, although infrequent, continue to be a problem as with the open method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neurological Study of Radial Nerve Conduction During Endoscopic Radial Artery Harvesting:An Intra‐Operative Evaluation

Endoscopic radial artery harvesting (ERAH) is a feasible and attractive minimally invasive approach for conduit procurement, however there have been concerns about a potential neurological damage occurring at the harvest limb site secondary to injury of the radial nerve during endoscopic harvesting. We present a case of ERAH in which we evaluated intraoperatively the characteristics of radial n...

متن کامل

Endoscopic radial artery harvesting may be the procedure of choice for coronary artery bypass grafting.

BACKGROUND This study assessed the neurologic and cosmetic outcome of the endoscopic radial artery harvesting (ERH) technique in coronary artery bypass grafting (CABG). METHODS AND RESULTS The study group comprised 257 consecutive patients who underwent CABG between January 2001 and August 2005 at Kyungpook National University Hospital. The first 157 patients (open group) underwent convention...

متن کامل

Endoscopic radial artery harvesting for coronary artery bypass grafting. A single center evolving experience.

AIM We sought to evaluate our experience with endoscopic radial artery harvesting for coronary artery bypass grafting (CABG). METHODS From October 2005 to June 2010, 50 patients who underwent endoscopic radial artery harvesting for an elective CABG were prospectively assessed for harvesting characteristics, complications, postoperative and mid-term outcomes. RESULTS There were 34 (68%) male...

متن کامل

Endoscopic radial artery harvesting procedure for coronary artery bypass grafting.

Development and adoption of endoscopic minimally invasive saphenous vein harvesting prompted its application to the radial artery in an effort to minimize surgical trauma. Recently, we reported that endoscopic radial artery harvesting was associated with better wound appearance and it proved to be safe and effective, with less pain and fewer wound complications than the open surgical technique....

متن کامل

Simultaneous endoscopic radial artery and great saphenous vein harvesting for redo coronary artery bypass grafting. A report of two cases.

AIM An ageing population and increase in patient co-morbidities are forcing cardiac surgeons to meticulously consider the benefits and risks of respective conduits and their harvesting techniques. CASE REPORTS Two cases of simultaneous endoscopic radial artery and great saphenous vein harvesting, for redo coronary artery bypass grafting, are presented. A shortage of venous conduits after prev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 74 2  شماره 

صفحات  -

تاریخ انتشار 2002