Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA.
نویسندگان
چکیده
Although dual-mobility sockets have been in clinical use for decades in other parts of the world, they recently gained popularity in the United States as an option for primary and revision total hip arthroplasty (THA). Improvements in dual-mobility socket technology include articulation with a metal insert impacted into a metal shell and a femoral head made of highly cross-linked polyethylene. The results and complications associated with the use of dual-mobility sockets employing these technologic advancements are not known. Specifically, intraprosthetic dislocation is a well-known complication of these implants and has been reported extensively in the literature. To the authors' knowledge, its occurrence in a modern dual-mobility socket has not been reported. The authors report a case of early intraprosthetic dislocation of a contemporary dual-mobility design used to convert a patient to THA after failed fixation of intertrochanteric hip fracture. At retrieval, there was evidence that the outer bearing may have ceased moving, causing localized focal impingement of the implant neck on the retentive ring. The authors theorized that external hip impingement (pelvic against trochanter) and previous surgery that led to the formation of scar tissue could have caused the outer bearing surface to cease its motion. This ultimately led to impingement of the femoral component neck on the retentive ring, which led to the intraprosthetic dislocation. Dual-mobility cups provide an attractive option to decrease wear and improve stability. Further research is needed to establish the ideal construct design and materials.
منابع مشابه
Early Intraprosthetic Dislocation of Dual- Mobility Total Hip Arthroplasty Implant Following Attempted Closed Reduction: A Case Report
Introduced in 1974 by Bousquet, the dual-mobility bearing for use in total hip arthroplasty (THA) confers increased jump distance and improved overall stability relative to conventional THA designs [1-3]. The dual-mobility bearing incorporates a relatively small (22-28mm) metal or ceramic femoral head press fit into a larger polyethylene liner which articulates with the acetabular component. Di...
متن کاملEarly Intraprosthetic Dislocation of a Dual Mobility Acetabular Construct after Total Hip Arthroplasty
INTRODUCTION The concept of a dual mobility (DM) cup has been in existence for more than 40 years and was initially popularized in Europe. Only recently has it started to garner attention in the United States. Its design, consisting of a small femoral head articulating within a larger polyethylene (PE) insert, which articulates with an outer shell, has found increasing use in patients that are ...
متن کاملDual poly liner mobility optimizes wear and stability in THA: opposes.
Total hip arthroplasty (THA) is an effective intervention for the treatment of arthrosis with excellent survivorship. Nonetheless, dislocation and osteolysis remain significant complications. A dual-mobility acetabular component has been advocated to improve stability and wear. Stability is imparted by increasing the effective femoral head size, which allows a larger range of motion (ROM) befor...
متن کاملEarly intraprosthetic dislocation in dual-mobility implants: a systematic review
BACKGROUND Dual mobility implants are subject to a specific implant-related complication, intraprosthetic dislocation (IPD), in which the polyethylene liner dissociates from the femoral head. For older generation designs, IPD was attributable to late polyethylene wear and subsequent failure of the head capture mechanism. However, early IPDs have been reportedly affecting contemporary designs. ...
متن کاملEarly Intraprosthetic Dislocation of A Dual Mobility Acetabular Construct
Dislocations represent one of the more common postoperative complications seen after total hip arthroplasty (THA) with estimates ranging from 0.2 to 7% in primary cases and as high as 25% in revision surgeries [1]. In the early 1970s, Giles Bousquet developed a dual mobility (DM) acetabular cup with the goal of reducing dislocation rates. The dual mobility (DM) design consists of two articulati...