Simultaneous determination of five polyether ionophores using liquid chromatography with one-step fluorescent derivatization.

نویسندگان

  • Koichi Inoue
  • Yukiko Miura
  • Misato Suzuki
  • Naoya Kishikawa
  • Tomoaki Hino
  • Naotaka Kuroda
  • Hisao Oka
چکیده

We present a selective method for simultaneous determination of five polyether ionophores such as salinomycin (SAL), monensin (MON), narasin (NAR), semduramicin (SEM) and lasalocid (LAS) in aquatic samples using a liquid chromatography with one-step fluorescent derivatization of 2-(4-hydrazinocarbonyl-phenyl) 4,5-diphenylimidazole (HCPI) and 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride hydrochloride (DIB-Cl). Fluorescent one-step derivatization for SAL, MON, NAR and SEM using HCPI and for LAS using DIB-Cl was monitored by an LC/fluorescence detector (E(x), 340 nm; E(m), 465 nm). Chromatographic separation was performed on a TSK-GEL ODS-120T (4.6 × 150 mm, 3 µm) column using a mobile phase of 0.1% formic acid in acetonitrile and 0.5 mM ammonium formate in water (70/30, v/v). The limits of detections were 0.01 µg/mL (50 pg) for LAS, 0.05 µg/mL (250 pg) for SAL, NAR and SEM, and 0.1 µg/mL (500 pg) for MON, respectively. The recoveries for water samples were indicated to be the range of 79.6 ± 6.4 - 99.0 ± 4.4% with associated precision values (between-day for 3 days) for repeatability. Based on solid-phase extraction, the limit of quantitation values indicated 0.1 ng/mL for SAL, MON, NAR and SEM, and 0.01 ng/mL for LAS in water samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

Utility of Experimental Design in Pre-Column Derivatization for the Analysis of Tobramycin by HPLC—Fluorescence Detection: Application to Ophthalmic Solution and Human Plasma

A novel, selective, and sensitive reversed phase high-performance liquid chromatography (HPLC) method coupled with fluorescence detection has been developed for the determination of tobramycin (TOB) in pure form, in ophthalmic solution and in spiked human plasma. Since TOB lacks UV absorbing chromophores and native fluorescence, pre-column derivatization of TOB was carried out using fluorescami...

متن کامل

Analysis of trace atrazine and simazine in environmental samples by liquid chromatography-fluorescence detection with pre-column derivatization reaction.

Coupled with off-line extraction, a pre-column derivatization liquid chromatographic fluorescence detection (LC-FL) procedure was developed for the determination of atrazine and simazine in soil, crop and water samples. Concentrations in real samples were expected to be at or below the low ng/g level, which requires pre-concentration of analytes and improved detection. 4-(2-Phthalimidyl) benzoy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2012