Development of a validated stability-indicating HPTLC method for rufinamide in bulk and its pharmaceutical dosage form.

نویسندگان

  • Apexa Patel
  • Arpit Patwari
  • Bhanubhai Suhagia
چکیده

A sensitive, selective, precise and stability indicating a high-performance thin layer chromatographic method for the analysis of rufinamide (Rf) in bulk drug and its formulations was developed and validated. The method employed thin layer chromatography aluminum plates precoated with silica gel 60 F254 as the stationary phase. The solvent system consisted of chloroform : methanol : glacial acetic acid (9 : 1 : 0.1 v/v/v). This system was found to give compact spots for Rf (Rf value of 0.68 ± 0.02). Rf was subjected to acid and alkali hydrolysis, oxidation, photodegradation and dry heat treatment. Also, the degraded products were well separated from the pure drug. Densitometric analysis of Rf was carried out in the absorbance mode at 210 nm, which is wavelength maxima for the degradant. The linear regression data for the calibration plots showed a good linear relationship with an r(2) of 0.9989 in the concentration range of 1,000-3,500 ng. The method was validated for precision, accuracy, ruggedness and recovery. The limits of detection and quantitation were 196.59 and 595.74 ng spot(-1), respectively. The drug undergoes degradation under acidic and basic conditions. All the peaks of degraded products were resolved from the standard drug with significantly different Rf values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

متن کامل

HPTLC-densitometry method development and validation for simultaneous determination of abacavir, lamivudine and zidovudine in combined dosage form

A simple, accurate and precise HPTLC- densitometry method for the simultaneousdetermination of abacavir, lamivudine and zidovudine in pharmaceutical tablet has beendeveloped. Separation of tablet components was performed on aluminum backed HPTLC plates(silica gel 60 F254 20×20 cm with 0.2 mm thickness, Camag, Muttenz, Switzerland ) usingmethanol : chloroform : acetonitrile (4 : 8 : 3 v/v). Good...

متن کامل

Development and validation of a stability indicating RP-HPLC method for the determination of Rufinamide

A stability-indicating RP-HPLC method was developed and validated for the determination of Rufinamide in tablet dosage forms using C 18 column (250 mm×4.6 mm, 5 μm) with mobile phase consisting of water-acetonitrile (40:60, v/v) with a flow rate of 0.8 mL/min (UV detection 215 nm). Linearity was observed over the concentration range 1.0-200 μg/mL (R2=0.9997) with regression equation y=113190 x+...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 52 10  شماره 

صفحات  -

تاریخ انتشار 2014