A tidally breathing model of ventilation, perfusion and volume in normal and diseased lungs.

نویسندگان

  • J S Yem
  • M J Turner
  • A B Baker
  • I H Young
  • A B H Crawford
چکیده

BACKGROUND To simulate the short-term dynamics of soluble gas exchange (e.g. CO2 rebreathing), model structure, ventilation-perfusion (VA/Q) and ventilation-volume (VA/VA) parameters must be selected correctly. Some diseases affect mainly the VA/Q distribution while others affect both VA/Q and VA/VA distributions. Results from the multiple inert gas elimination technique (MIGET) and multiple breath nitrogen washout (MBNW) can be used to select VA/Q and VA/VA parameters, but no method exists for combining VA/Q and VA/VA parameters in a multicompartment lung model. METHODS We define a tidally breathing lung model containing shunt and up to eight alveolar compartments. Quantitative and qualitative understanding of the diseases is used to reduce the number of model compartments to achieve a unique solution. The reduced model is fitted simultaneously to inert gas retentions calculated from published VA/Q distributions and normalized MBNWs obtained from similar subjects. Normal lungs and representative cases of emphysema and embolism are studied. RESULTS The normal, emphysematous and embolism models simplify to one, three and two alveolar compartments, respectively. CONCLUSIONS The models reproduce their respective MIGET and MBNW patient results well, and predict disease-specific steady-state and dynamic soluble and insoluble gas responses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive Pulmonary Evaluation of Emphysematous Mice using Hyperpolarized Xe MRI/MRS under Spontaneous Breathing Mode

Introduction: Hyperpolarized (HP) noble gas MRI and MRS in the lungs on spontaneous breathing mice is expected as a valuable modality for drug discovery or development of the methods for evaluating physiological changes. Since the measurements under the spontaneous breathing condition are fully non-invasive protocol without using mechanical ventilation, this technique allows a long-term and the...

متن کامل

A Model of the Respiratory System in the Newborn Infant

A dynamic mathematical model is presented which successfully simulates the respiratory control system of the newborn infant in different physiological conditions. The primary objective in constructing this model has been to provide a simulation aid in the investigation of maturation of the respiratory system, and the respiratory disorders during the newborn period, without the need for invasive...

متن کامل

Spurious lung perfusion ventilation defect on planar ventilation-perfusion scan detected by SPECT imaging

Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilation-perfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed multiple mismatched defects through...

متن کامل

Regional lung function in bilateral diaphragmatic paralysis.

1. The distribution of regional function in the lungs of six patient with bilateral diaphragmatic paralysis was investigated by continuous inhalation and infusion of the radioactive gases 81mKr and 85mKr during tidal breathing. 2. In the supine and right lateral decubitus postures the vertical distribution of ventilation per unit alveolar volume was less in the dependent zones, the reverse of t...

متن کامل

Evaluation of estimates of alveolar gas exchange by using a tidally ventilated nonhomogenous lung model.

The purpose of this study was to evaluate algorithms for estimating O2 and CO2 transfer at the pulmonary capillaries by use of a nine-compartment tidally ventilated lung model that incorporated inhomogeneities in ventilation-to-volume and ventilation-to-perfusion ratios. Breath-to-breath O2 and CO2 exchange at the capillary level and at the mouth were simulated by using realistic cyclical breat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 97 5  شماره 

صفحات  -

تاریخ انتشار 2006