Simultaneous spectrophotometric determination of nitrite and nitrate by flow-injection analysis.

نویسندگان

  • M J Ahmed
  • C D Stalikas
  • S M Tzouwara-Karayanni
  • M I Karayannis
چکیده

An automatic direct spectrophotometric method for the simultaneous determination of nitrite and nitrate by flow-injection analysis has been developed. Nitrite reacts with 3-nitroaniline in the presence of hydrochloric acid (0.96-1.8 M HCl or pH 0.5-0.7) to form a diazonium cation, which is subsequently coupled with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a stable purple azo dye, the absorbance of which is measured at 535 nm. Nitrate is reduced on-line to nitrite in a copper-coated cadmium column which is then treated with azo dye reagent and the absorbance due to the sum of nitrite and nitrate is measured; nitrate is determined from the difference in absorbance values. A copper column incorporated into the reaction manifold before the copperised cadmium column not only improves the long-term accuracy, but also extends the life time of the copperised cadmium column. Various analytical parameters, such as effect of acidity (pH), flow rate, sample size, dispersion coefficient, time, temperature, reagent concentration and interfering species, were studied. The calibration graphs were rectilinear for 0.1-3.5 mug ml(-1) of NO(3) and 10 ng ml(-1)-2.2mug ml(-1) of NO(2). The method is successfully applied to some food samples (meat, flour and cheese), environmental waters (inland and surface), beer and soil samples. Up to 30 samples can be analysed per hour with a relative precision of approximately 0.1-2%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric simultaneous determination of nitrite, nitrate and ammonium in soils by flow injection analysis.

A new rapid flow injection procedure for the simultaneous determination of nitrate, nitrite and ammonium in single flow injection analysis system is proposed. The procedure combines on-line reduction of nitrate to nitrite and oxidation of ammonium to nitrite with spectrophotometric detection of nitrite by using the Griess-Ilosvay reaction. The formed azo dye was measured at 543 nm. The influenc...

متن کامل

Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples.

A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxyb...

متن کامل

Sequential flow injection spectrophotometric determination of nitrite and nitrate in various samples

A direct spectrophotometric method has been developed for the sequential determination of nitrite and nitrate by flow injection analysis (FIA). The method is based on the reaction of nitrite with safranine O to form a diazonium salt which caused the reddish-orange dye colour of the solution to be changed to blue in acidic media, and which absorbs at 520 nm. The injected sample in the flow injec...

متن کامل

Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 – 1000 μg N L (R = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 μg N L and relative standard deviatio...

متن کامل

Determination of nitrite and nitrate in water samples by an automated hydrodynamic sequential injection method.

An automated hydrodynamic sequential injection (HSI) system with spectrophotometric detection was developed. Thanks to the hydrodynamic injection principle, simple devices can be used for introducing reproducible microliter volumes of both sample and reagent into the flow channel to form stacked zones in a similar fashion to those in a sequential injection system. The zones were then pushed to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 43 7  شماره 

صفحات  -

تاریخ انتشار 1996