Electrical impedance tomography (EIT) is an emerging new imaging modality not yet routinely used in a clinical setting. The generation of EIT scans is based on the non-invasive measurement of electrical properties of tissues which does not require the use of radiation. Thoracic EIT examinations have been shown to track changes in regional lung volumes at scan rates of up to 40-50 scans/s. Experimental and clinical studies indicate the potential of EIT in monitoring regional lung ventilation and aeration at the bedside. Mechanically ventilated patients with acute lung injury and acute respiratory distress syndrome (ARDS) might benefit from possible continuous monitoring of their regional lung function by EIT which could be used to optimise the ventilator settings and minimise the ventilator-induced lung injury. This review explains the measuring principle of EIT and the analysis of regional EIT signals which allow the assessment of regional lung ventilation, aeration and potentially also lung perfusion. Protective lung ventilation using low tidal volumes and adequate positive end-expiratory pressures, recruitment manoeuvres, surfactant administration, prone posture, restricted fluid administration, assisted ventilation allowing spontaneous breathing, partial liquid ventilation, administration of pulmonary vasoactive, anti-inflammatory and antioxidant agents are used or considered in the management of ARDS patients. EIT is capable of monitoring the pulmonary effects of many of these therapeutic procedures. This is documented by examples from experimental and clinical EIT studies and by references to relevant EIT literature. The perspectives and limitations of EIT monitoring are also addressed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of regional ventilation in acute respiratory distress syndrome by electrical impedance tomography.

Mechanical ventilation in acute respiratory distress syndrome (ARDS) incurs a risk of ventilator-associated lung injury (VALI) from inhomogeneous conditions and different properties of dependent and non-dependent lung regions at risk of atelectasis and overdistension, respectively. Electrical impedance tomography (EIT) offers regional ventilation assessment to optimise treatment with mechanical...

متن کامل

Use of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review

Thoracic electrical impedance tomography is a real-time, noninvasive monitoring tool of the regional pulmonary ventilation distribution. Its bedside use in patients with acute respiratory distress syndrome has the potential to aid in alveolar recruitment maneuvers, which are often necessary in cases of refractory hypoxemia. In this case report, we describe the monitoring results and interpretat...

متن کامل

Electrical impedance tomography as ventilation monitoring in ICU patients

Electrical impedance tomography (EIT), as a monitoring tool of regional lung ventilation, is radiation-free imaging with high temporal resolution. The most important purpose of EIT is to visualize the distribution of tidal volume in different lung regions especially between dependent (dorsal in supine patients) and non-dependent (ventral in supine patients) regions. Many clinical studies evalua...

متن کامل

Electrical impedance tomography: so close to touching the holy grail

Electrical impedance tomography is a new technology giving us lung imaging that may allow lung function to be monitored at the bedside. Several applications have been studied to guide mechanical ventilation at the bedside with electrical impedance tomography. Positive end-expiratory pressure trials guided by electrical impedance tomography are relevant in terms of recruited volume or homogeneit...

متن کامل

Monitoring of the lung fluid movement and estimation of lung area using Electrical Impedance Tomography: A Simulation Study

Patients suffering from the acute respiratory distress syndrome (ARDS) requires thoracic electrical impedance tomography (EIT) for the monitoring their conditions ranging from dynamic shifting of body fluids to lung aeration right at the bedside. More objectively, EIT-derived numeric parameters would help the physician to evaluate the state of the lung. Thus, here we have performed a Finite Ele...