A Comparison of Positron Emission Tomography and Colonoscopy for the Detection of Advanced Colorectal Neoplasms in Subjects Undergoing a Health Check-Up

نویسندگان

  • Shu-Wei Huang
  • Chen-Ming Hsu
  • Wen-Juei Jeng
  • Tzu-Chen Yen
  • Ming-Yao Su
  • Cheng-Tang Chiu
چکیده

BACKGROUND & AIMS There is no agreement as to whether F-18 fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) screening for advanced colorectal neoplasms is meaningful. This retrospective study was undertaken to determine whether FDG PET/CT may be a valuable screening tool for the detection of advanced colorectal neoplasms. METHODS A retrospective review of the records of 1,109 FDG PET/CT scans acquired from January 2007 to December 2011 was performed. Colonoscopy and FDG PET/CT imaging were performed within two days of each other. The results of colonoscopy were taken as the gold standard, either with or without the results of the histopathological examination. An advanced neoplasm was defined as the presence of a malignant tumor, an adenoma ≥1 cm, or histological evidence of high-grade dysplasia or significant villous components. RESULTS A total of 36 subjects had advanced colorectal neoplasms detected by colonoscopy (totaling 38 neoplasms). Six of the 38 neoplasms were also detected by FDG PET/CT. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of FDG PET/CT in the detection of advanced colorectal neoplasms were 15.8% (6/38), 99.1% (1063/1073), 37.5% (6/16), 97.1% (1063/1095), and 96.2% (1069/1111) respectively. The presence of lesions with an endoscopic size ≤1.5 cm (P<0.001) and low-grade dysplasia (P<0.001) were the main predictors of false-negative FDG PET/CT findings. CONCLUSIONS We conclude that FDG PET/CT screening of advanced colorectal neoplasms is unwarranted, especially in the presence of lesions with an endoscopic size ≤1.5 cm or low-grade dysplasia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

Comparison of Count Normalization Methods for Statistical Parametric Mapping Analysis Using a Digital Brain Phantom Obtained from Fluorodeoxyglucose-positron Emission Tomography

Objective(s): Alternative normalization methods were proposed to solve the biased information of SPM in the study of neurodegenerative disease. The objective of this study was to determine the most suitable count normalization method for SPM analysis of a neurodegenerative disease based on the results of different count normalization methods applied on a prepared digital phantom similar to one ...

متن کامل

Importance of defect detectability in Positron Emission Tomography imaging of abdominal lesions

Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...

متن کامل

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013