Electrodes for 24 hours pH monitoring--a comparative study.
نویسندگان
چکیده
Three pH electrodes in clinical use were examined--(1) antimony electrode with remote reference electrode (Synectics 0011), (2) glass electrode with remote reference electrode (Microelectrodes Inc. MI 506) and (3) combined glass electrode with integral reference electrode (Radiometer GK2801C). In vitro studies showed that both glass electrodes were similar and superior to the antimony electrode with respect to response time, drift, and sensitivity. The effect of the siting of the reference electrode on the recorded pH was examined in five human volunteers. The pH reading using a remote skin reference electrode was higher by a mean of 0.3 pH units (range 0.0-0.6) in the stomach, lower by 0.65 pH units (0.5-0.8) in the duodenum and lower by 0.3 pH units (0.0-0.6) in the oesophagus than that simultaneously obtained with an intraluminal reference electrode. Buccal reference electrodes gave similar readings to skin. Combined reference and glass pH electrodes are recommended for 24-hour ambulatory pH monitoring.
منابع مشابه
The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.
Intraluminal pH monitoring in man should be performed with disposable multichannel assemblies that allow recordings at multiple sites and prevent transmission of infection. Currently available glass electrodes are unsuitable for this purpose because of their size and price. We have thus constructed and tested a small, combined ion sensitive field effect transistor (ISFET) pH electrode incorpora...
متن کاملComparative study of glass and antimony electrodes for continuous oesophageal pH monitoring.
Oesophageal pH monitoring data are influenced by numerous patient or technique related factors, or both. In this study, data recorded with glass microelectrodes or antimony electrodes, both with external cutaneous Ag/AgCl reference electrodes, connected to two different recording devices are compared. Pearson correlation coefficients regarding the reflux index (% of the investigation time with ...
متن کاملLiquid-containing Refluxes and Acid Refluxes May Be Less Frequent in the Japanese Population Than in Other Populations: Normal Values of 24-hour Esophageal Impedance and pH Monitoring
Background/Aims Twenty-four-hour esophageal impedance and pH monitoring allows detection of all types of reflux episodes and is considered the best technique for identifying gastroesophageal refluxes. However, normative data for the Japanese population are lacking. This multicenter study aimed to establish the normal range of 24-hour esophageal impedance and pH data both in the distal and the p...
متن کاملEffect of general anaesthesia on prolonged intraoesophageal pH monitoring.
Investigation of gastro-oesophageal reflux often includes endoscopy, usually under general anaesthesia, and pH monitoring. In most cases, the pH probe is passed when the child is awake and is poorly tolerated. The effect of general anaesthesia on pH monitoring is unknown. The aim of the study was to determine if placing the probe in the anaesthetised child gives a representative pH study. Twent...
متن کاملComparative study of two modes of gastroesophageal reflux measuring: conventional esophageal pH monitoring and wireless pH monitoring.
CONTEXT Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patient's routine activities. Wireless pH monitoring was developed to avoid these restrictions. OBJECTIVE To compare the first 24 hours of the conventional and wireless pH monitoring, positioned 3 cm abov...