Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
نویسندگان
چکیده
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 ± 0.01 in the recoil energy range 40 keV 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator of the decay time constant for 6 keV < Eee < 30 keV nuclear recoil events is equal to 21.0 ns ± 0.5 ns. It is observed that for electron recoils T0 rises slowly with energy, having a value ∼ 30 ns at Eee ∼ 15 keV. Electron and nuclear recoil pulse-shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse-shape. PACS: 95.35.+d, 29.40.Mc, 61.25.Bi
منابع مشابه
Scintillation Pulse Shape Discrimination in a Two-Phase Xenon Time Projection Chamber
The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio simultaneously to obtain a leakage below that achievable by either discriminant alone. A Monte Carlo is used to show that the dominant fluctuation in the pulse shape...
متن کاملScintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV
The scintillation efficiency of liquid xenon for nuclear recoils has been measured to be nearly constant in the recoil energy range from 140 keV down to 5 keV. The average ratio of the efficiency for recoils to that for gamma-rays is found to be 0.19±0.02. PACS codes: 29.40.Mc, 78.70.-g, 78.60.-b, 95.35.+d
متن کاملMeasuring Electron Response in NaI(Tl) using Compton Coincidence Technique
The scintillation efficiency of electron recoils in liquid xenon (LXe) is not well measured at low energies. The Compton coincidence technique (CCT) is set up using a NaI(Tl) detector and HPGe detector to measure the energy dependence of the light yield in the NaI(Tl) detector from which we can extract the scintillation effieciency. This technique allows for the detection of low energy electron...
متن کاملR&D Results and Status of the XENON Dark Matter Experiment
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xenon nuclei. With a fiducial mass of 1000 kg of liquid xenon, a sufficiently low threshold of 16 keV recoil energy and an unrejected background rate of 10 events per year, XENON would be sensitive to a WIMP-nucleon interaction cross secti...
متن کاملThe XENON Dark Matter Search Experiment
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe the lowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid...
متن کامل