Determination of heavy metals and rare earth elements in environmental samples by ICP-MS after solid phase preconcentration with chelating resin fibers and anion exchanger filters.

نویسندگان

  • Kyue-Hyung Lee
  • Yoshiki Muraoka
  • Mitsuko Oshima
  • Shoji Motomizu
چکیده

A solid phase collection/concentration method using anion exchanger filters and a small syringe packed with chelating resin fibers is adopted as a preconcentration tool for trace elements and a separation tool for matrices in aqueous samples prior to the measurement by inductively coupled plasma-mass spectrometry (ICP-MS). The effects of fiber volume, sample volume, eluent volume, and sample flow rate on metal recoveries were investigated in detail to obtain optimum pretreatment conditions. Several heavy metals (HMs) such as, V, Mn, Co, Ni, Cu, Zn, Ga, Cd, Pb, Th and U, as well as 14 rare earth elements (REEs) in sample solutions at pH 6 were quantitatively collected on the solid phase. These adsorbed elements were completely recovered by eluting with 2 ml of 1.0 M nitric acid. At pH 6, more than 99% of alkali and alkaline earth metals in sample solutions were eliminated. The proposed method was evaluated by analyzing two standard reference materials (SRM): peach leaves (NIST 1547) and pond sediment (NIES No. 2). The solid samples were decomposed by microwave-heating and pressurizing acid digestion technique, and then treated by the proposed syringe-type pretreatment method, followed by the ICP-MS measurement. The analytical results for HMs in the SRMs obtained by the present method agreed well with the certified values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sample pretreatment using chitosan-based chelating resin for the determination of trace metals in seawater samples by inductively coupled plasma-mass spectrometry.

A sample-pretreatment method using a chitosan-based chelating resin, ethylenediamine-N,N,N'-triacetate-type chitosan (EDTriA-type chitosan), was developed for the preconcentration of trace metals in seawater and separation of the seawater matrix prior to their determination by inductively coupled plasma-mass spectrometry (ICP-MS). The resin showed very good adsorption for transition metals and ...

متن کامل

Multielement determination of trace metals in river water (certified reference material, JSAC 0301-1) by high efficiency nebulization ICP-MS after 100-fold preconcentration with a chelating resin-packed minicolumn.

The determination of 34 trace metals in a river water certified reference material (CRM), i.e. JSAC 0301-1, which was issued by the Japan Society for Analytical Chemistry in January 2004, was performed by ICP-MS with a high efficiency nebulizer after preconcentration with a laboratory-made chelating resin-packed minicolumn, with which trace metals were concentrated 100-fold from 50 mL of a rive...

متن کامل

Preconcentration of rare earth elements on silica gel loaded with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one prior to their determination by ICP-AES.

A new chelating resin, silica gel loaded with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP), was prepared and used for the preconcentration of trace amounts of rare earth elements (REEs) in water samples prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). REEs (La, Eu, Yb and Y) were quantitatively retained on the column packed with modified sili...

متن کامل

Synthesis of cross-linked chitosan modified with the glycine moiety for the collection/concentration of bismuth in aquatic samples for ICP-MS determination.

A chelating resin, cross-linked chitosan modified with the glycine moiety (glycine-type chitosan resin), was developed for the collection and concentration of bismuth in aquatic samples for ICP-MS measurements. The adsorption behavior of bismuth and 55 elements on glycine-type chitosan resin was systematically examined by passing a sample solution containing 56 elements through a mini-column pa...

متن کامل

The Preconcentration and Determination of Pb2+, Cu2+, Co2+, Ni2+, Fe2+ and Zn2+ Elements in Water Samples Using Citrate Form of Anion-Exchange Resin

Lead, copper, cobalt, nickel, iron and zinc ions form monocitrate complexes (negative charge) in citrate solution which is absorbed on the citrate form of anion-exchange resins (citrate as counter ion) y exchange of citrate ion with citrate complexes. These are subsequently recovered from the resin by 0.5M ammonium citrate eluent at pH 2.0. Under optimized conditions, quantitative recovery ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2004