Postoperative Assessment of Pedicle Screws and Management of Breaches: A Survey among Canadian Spine Surgeons and a New Scoring System
نویسندگان
چکیده
Study Design This study was designed as a survey amongst Canadian spine surgeon to determine a scoring system to standardize pedicle screw placement assessment. Purpose This study aimed to obtain and analyze the opinions of spine surgeons regarding the assessment of pedicle screw accuracy, with the goal of establishing clinical guidelines for interventions for malpositioned pedicle screws. Overview of Literature Accurate placement of pedicle screws is challenging, and misalignment can lead to various complications. To date, there is no recognized gold standard for assessing pedicle screw placement accuracy. The literature is lacking studies attempting to standardize pedicle screw placement accuracy assessment. Methods A survey of the clinical methods and imaging criteria that are used for assessing pedicle screw placement accuracy was designed and sent to orthopedic and neurosurgery spine surgeons from the Canadian Spine Society for their anonymous participation. Results Thirty-five surgeons completed the questionnaire. The most commonly used modalities for assessing pedicle screw position postoperatively were plain X-rays (97%) and computed tomography (CT, 97%). In both symptomatic and asymptomatic patients, the most and least worrisome breaches were medial and anterior breaches, respectively. The majority of surgeons tended not to re-operate on asymptomatic breaches. More than 60% of surgeons would re-operate on patients with new-onset pain and a ≤4-mm medial or inferior breach in both thoracic and lumbar regions. If a patient experienced sensory loss and a breach on CT, in either the thoracic or lumbar levels, 90% and 70% of the surgeons would re-operate for a medial breach and an inferior breach, respectively. Conclusions Postoperative clinical presentation and imaging findings are crucial for interpreting aberrant pedicle screw placement. This study presents a preliminary scoring system for standardizing the classification of pedicle screws.
منابع مشابه
Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system.
STUDY DESIGN Controlled, cadaveric implantation trial. OBJECTIVE To evaluate the effect of a robotic guidance system on screw placement accuracy, amount of radiation exposure, and length of procedure time during percutaneous pedicle screw implantation. SUMMARY OF BACKGROUND DATA Pedicle screws are associated with low complication rates, and several computer-assisted image guidance systems e...
متن کاملThe Clinical Experience of Computed Tomographic-Guided Navigation System in C1-2 Spine Instrumentation Surgery
OBJECTIVE To identify the accuracy and efficiency of the computed tomographic (CT)-based navigation system on upper cervical instrumentation, particularly C1 lateral mass and C2 pedicle screw fixation compared to previous reports. METHODS Between May 2005 and March 2014, 25 patients underwent upper cervical instrumentation via a CT-based navigation system. Seven patients were excluded, while ...
متن کاملStimulation of Pedicle Screws with Diathermy: Is it a Viable Option to Detect Breaches?
Background: To analyse use of monopolar diathermy stimulation of pedicle screws in order to improve breach detection. Methods: Prospective single-blind study. Patients with preoperative neurological deficit excluded. Pedicle screws inserted freehand into thoracic and lumbar spine. Monopolar diathermy in “cutting” mode at half the strength used for actual cutting purpose was used to stimulate th...
متن کاملPreoperative Planning and Simulation for Pedicle Screw Insertion Using Computed Tomography-Based Patient Specific Volume Rendering Combined with Projection Fluoroscopy
Pedicle screw insertion has been a standard processes for stabilizing the spine [1]. Spinal surgery can be classified as either minimally invasive or open, based on differences in the size of incisions: minimally invasive surgery implants the pedicle screw based on intraoperative fluoroscopic images to ensure the entry point and trajectory, and open surgery implants the pedicle screw based on i...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کامل