Development of a multichannel dispersion interferometer at TEXTOR.

نویسندگان

  • A Lizunov
  • P Bagryansky
  • A Khilchenko
  • Yu V Kovalenko
  • A Solomakhin
  • W Biel
  • H T Lambertz
  • Yu Krasikov
  • M Mitri
  • B Schweer
  • H Dreier
چکیده

The design and main characteristics of 14-channel dispersion interferometer for plasma profile measurement and control in TEXTOR tokamak are presented. The diagnostic is engineered on the basis of modular concept, the 10.6 microm CO(2) laser source and all optical and mechanical elements of each module are arranged in a compact housing. A set of mirrors and retroreflectors inside the TEXTOR vacuum vessel provides full coverage of the torus cross section with 12 vertical and two diagonal lines of sight, no rigid frame for vibration isolation is required. Results of testing of the single-channel prototype diagnostic and the pilot module of the multichannel dispersion interferometer are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bayesian experimental design of a multichannel interferometer for Wendelstein 7-X.

Bayesian experimental design (BED) is a framework for the optimization of diagnostics basing on probability theory. In this work it is applied to the design of a multichannel interferometer at the Wendelstein 7-X stellarator experiment. BED offers the possibility to compare diverse designs quantitatively, which will be shown for beam-line designs resulting from different plasma configurations. ...

متن کامل

First results from the multichannel interferometer system on HSX

Measuring the equilibrium electron density distribution and its response to perturbations provides important information to magnetically confined plasma research. A multichannel interferometer system is now routinely operating on the new quasihelically symmetric stellator ~HSX! to measure the equilibrium profile and electron density dynamics. The interferometer system has nine viewing chords wi...

متن کامل

Multichannel Kondo approach to the cuprate and recent laser ARPES data

The existing theoretical approaches have been unable to confront the large corpus of outstanding data on the cuprate superconductor in a persuasive and unified manner. There is a general opinion now growing that these theories miss some essential points. We propose one based on multichannel Kondo effect that is physically justifiable and confronts the data adequately. In addition to earlier da...

متن کامل

Electrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals using a Michelson interferometer

Fabricating an electrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals (H-PDLC) using a Michelson interferometer is reported. Simplicity of the method and possibility of fabricating different focal length lenses in a single set up are among the advantages of the method. It is demonstrated that the Fresnel structured zone plate acts as a cylindrica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 79 10  شماره 

صفحات  -

تاریخ انتشار 2008