The effect of ventricular pacing on measurements of left ventricular function: a comparison between echocardiographic methods and with radionuclide ventriculography.
نویسندگان
چکیده
AIMS Different methods exist for measuring left ventricular function echocardiographically; each may be error prone due to the abnormal pattern of ventricular activation during pacing. METHODS AND RESULTS Echocardiography was undertaken on 307 patients with permanent pacemakers; a subset of 57 underwent radionuclide ventriculography. Intrinsic and paced beats were analysed for left ventricular function by: Simpson's bi-plane, Teicholz M-mode, wall-motion scoring and 'eyeball' assessment. Agreement between techniques and with radionuclide ventriculography were compared according to intrinsic or paced beats. Echocardiographic measures of ejection fraction give mean values 5% higher than radionuclide ventriculography (Simpson's 30+/-9%, vs. Teicholz 30+/-13% vs. radionuclide ventriculography 25+/-9%, p=0.03). Agreement between Simpson's, Teicholz and radionuclide ventriculography by Bland-Altman analysis showed poor agreement (Simpson's vs. Teicholz range (4xSD)=57%, Simpson's vs. radionuclide ventriculography=36%, Teicholz vs. radionuclide ventriculography=46%, p=0.02), the level of agreement deteriorates with ventricular pacing (Simpson's vs. Teicholz range=61%, Simpson's vs. radionuclide ventriculography=34%, Teicholz vs. radionuclide ventriculography=47%, p=0.02). The correlation between wall motion analysis and radionuclide ventriculography is moderately poor (all subjects r=0.58, ventricular pacing r=0.52, not pacing r=0.66). CONCLUSION Echocardiography and radionuclide ventriculography are the only non-invasive techniques to assess left ventricular function in the paced population. Results are poorly interchangeable and the accuracy of any comparison dependent on the underlying rhythm.
منابع مشابه
Comparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method
Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملMeasurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images
Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...
متن کاملEvaluation of Cardiac Function in Patients with Thalassemia Intermedia
Abstract Background Thalassemia intermedia is a variety of beta thalassemia which shows clinical symptoms somewhere between asymptomatic carriers and thalassemia major. Cardiac dysfunctions due to chronic anemia and hemosiderosis are the major causes of death in these patients. The purpose of this study is to evaluate cardiac function in these patients by echocardiography. Materials and Met...
متن کاملReference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2006