Multigated blood-pool imaging using heart sounds.
نویسندگان
چکیده
A method to trigger multigated blood-pool (MGBP) acquisition using both the first and second heart sound has been developed. The heart sound gating (HSG) circuitry identifies, individually, both the first (S1) and second (S2) heart sounds from their timing relationship alone, and provides two trigger points during the cardiac cycle. First heart sound gating may be performed to assess the systolic ejection portion of the cardiac cycle, with S2 gating utilized for reproduction of the diastolic filling portion of the cycle. Heart sound gating has been applied to twenty patients who underwent analysis of left ventricular function, and compared to conventional ECG-gated MGBP. Left ventricular ejection fractions calculated from MGBP studies using a first and a second heart sound trigger correlated well with conventional ECG gated acquisitions in patients adequately gated by HSG and ECG. Heart sound gating may be utilized in patients with rapidly changing heart rates, as S1 and S2 precisely define end-diastole and end-systole, respectively, and in situations when the ECG is inadequate for gating purposes.
منابع مشابه
Summary Cardiac Pool Scintigraphy Using the Solid-State Digirad 2020tc ImagerTM —Comparison with the Conventional Anger-Type Gamma Camera Using Moving Cardiac Phantom—
Movable gamma camera, 2020tc ImagerTM, was light miniaturized using Si photodiode as a semiconductor sensor instead of photomultiplier tubes. To validate performance of this new camera in cardiac pool scintigraphy, multigated equilibrium radionuclide ventriculography using the moving cardiac phantom was performed with 2020tc Imager and a conventional Agner-type gamma camera (PRISM 3000). [Metho...
متن کاملRoutinely performed multigated blood pool imaging (MUGA) as a predictor of postoperative complications of lung resection. A two-year retrospective.
The results of routinely performed multigated blood pool studies (MUGA) were compared with the presence of postthoracotomy complications in 46 adult men in a retrospective chart review. Pulmonary function measurements were also examined in relation to the presence of complications experienced. There was only one death, but survivable complications were not predicted by the MUGA results. The add...
متن کاملObserver variance in the qualitative evaluation of left ventricular wall motion and the quantitation of left ventricular ejection fraction using rest and exercise multigated blood pool imaging.
متن کامل
Ventricular ejection fraction in patients with dilated cardiomyopathy calculated by gated blood pool SPET processing software: correlation with multigated acquisition and first pass radionuclide ventriculography.
This study was performed to find out the left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) in patients with dilated cardiomyopathy (DCM) by using commercially available automated gated blood pool scintigraphy (GBPS) processing software and to correlate it with first pass radionuclide ventriculography (FPRNV) and planar multigated acquisition (MUGA). Howe...
متن کاملNano Liposomes labeled with 99mTc-HMPAO, A Novel Agent for Blood Pool Imaging
In-vitro labeling of RBC with 99mTc is an intricate procedure and there is always a need foran alternate blood pool imaging agent. The aim of this study was to prepare an effective nanosized liposome (NLs) similar to human RBC for blood pool scintigraphy. This study formulatesPEG-NLs and non-PEG-NLs using film method plus high pressure homogenization technique.Biodistribution studies were perfo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 32 8 شماره
صفحات -
تاریخ انتشار 1991