Sensitive radioimmunoassay for digoxin in plasma and urine.
نویسندگان
چکیده
A reproducible and sensitive radioimmunoassay for digoxin in either serum, plasma or urine is described. Using 0.5 ml of serum or plasma, the assay sensitivity is 0.05 ng of digoxin/ml. The antiserum and tracer solutions employed are available in a kit sold in the United States. All other reagents were prepared in the laboratory. The assay allows measurement of digoxin in plasma or serum for 96 hours after single 0.5 mg doses of digoxin; this is necessary in human bioavailability studies to accurately estimate the total area under the digoxin concentration, time curve from zero to infinite time. In contrast, with the kit assay, employing 0.2 ml of plasma or serum, it has been reported that the 12 hr serum digoxin levels, after single 0.5 mg doses, are, in most subjects, below the sensitivity limit (about 0.5 ng/ml) of the assay.
منابع مشابه
Digoxin-like immunoreactivity in normal human plasma and urine, as detected by a solid-phase radioimmunoassay.
Reports on the presence of digoxin-like immunoreactive substance(s) (DLIS) in the plasma and urine of several animal species and a few human test subjects prompted us to undertake to confirm the presence of DLIS in plasma and urine of normal persons and to investigate some characteristics of this antibody-DLIS binding. For this purpose we used a modified radioimmunoassay kit involving antidigox...
متن کاملMeasurement of plasma digoxin concentration by radioimmunoassay.
A rapid, sensitive, and precise method for measuring the plasma digoxin concentration has been developed with the radioimmunoassay technique. Seventy patients receiving digoxin were shown to have plasma digoxin concentrations between 0.4 and 5 ng./ml. Preliminary studies show that though there is a positive correlation between total daily dose and the plasma digoxin concentration, the relations...
متن کاملPlasma and myocardial digoxin concentrations in patients on oral therapy.
Methods are now available which are sensitive enough to detect digoxin concentration to levels of 5 mug./ml. Hitherto the degree of sensitivity of specific chemical methods was not acceptable for clinical application. Digoxin-specific antibodies have recently been prepared (Butler and Chen, 1967), and a test based on the radioimmunoassay principle has now been used to measure plasma digoxin lev...
متن کاملRelationship between plasma concentration and dose of digoxin in patients with and without renal impairment.
The purpose of this study was to determine if there is a linear relationship between oral doses of digoxin and various measurements of steady-state digoxin plasma concentration and urinary excretion in patients with wide range of renal function. Ten patients (mean age 58 years) with creatinine clearances greater than 50 ml/min/1.73 m2 BSA (mean creatinine clearance 80 ml/min/1.73 m2 BSA) and ni...
متن کاملAwaiwl of diioxin bioavailabitity and phamecokinstics in relation to cardiac therapy
Butler and Chen’ first reported on the preparation of digoxin-specific antibodies. Later, Smith and associates2s3 characterized the antibodies2 and developed a radioimmunoassay for digoxin in serum or plasma.3 Subsequently, it was shown that antibodies present in commerciaIly available antiserum were not specific for digoxin, but that digoxin, digoxigen-mono-digotoxoside, and digoxigen-bis-digi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Steroids
دوره 29 6 شماره
صفحات -
تاریخ انتشار 1977