Comparison of B-Mode with B-Flow Sonography for the Evaluation of Femoral Arteries in Infants.
نویسندگان
چکیده
Purpose To evaluate femoral arteries (FAs) in infants in the context of catheter angiography with B-mode (BMS) and B-flow sonography (BFS) and to compare both methods for vessel delineation and reliability of vessel diameter measurements. Methods 21 consecutive infants who underwent ultrasound for the evaluation of FAs before or after cardiac catheterization were retrospectively included in this study. The diameter of the FAs and the maximum length of the vessel section displayed on a single ultrasound plane were recorded by two radiologists for BMS and BFS. The visual image quality was rated by one observer. Statistics included intraclass correlation coefficient, Bland-Altman analysis, Fisher´s exact test and t-test. Results The intraobserver as well as interobserver correlation was excellent for BMS (0.7922 and 0.6521) and BFS (0.8094 and 0.7637). The Bland-Altman analysis revealed limits of agreement for BMS between +/-0.73 mm (intraobserver) and +/-0.55 mm (interobserver) and for BFS between +/-0.83 mm (intraobserver) and +/-0.7 mm (interobserver). BFS allowed visualization of a longer stretch of the FA than BMS (length 3.54 +/-0.85 vs. 2.21 +/-0.9 cm, p < 0.0001). The image quality was significantly higher for BFS (p = 0.0043). Conclusion Since BFS shows excellent reproducibility for vessel measurements and superior image quality in infants, if available, BFS should be included in standard protocols when realistic measurements are required. Key Points · B-flow sonography offers high image quality for the evaluation of femoral arteries.. · Femoral artery diameter measurements performed with B-flow sonography show excellent reproducibility.. · If available, additional B-flow sonography of femoral arteries in infants is recommended.. Citation Format · Groth M, Dammann E, Arndt F et al. Comparison of B-Mode with B-Flow Sonography for the Evaluation of Femoral Arteries in Infants. Fortschr Röntgenstr 2017; 189: 1161 - 1167.
منابع مشابه
Normal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs
Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...
متن کاملمعرفی یک مورد نادر و آتیپیک واسکولیت کاوازاکی در بالغین
Kawasaki is an acute multisystemic disease with high fever in infants. Kawasaki is an unknown vasculitis that involves small and moderate size arteries especially coronary vessels. Clinical manifestations of Kawasaki are nonspecific and consist of persistant fever for more than 5 days, maculopapular skin rash, mucosal inflamation, bilateral conjunctivitis, neck lymphadenopathy, erythema and...
متن کاملStudy of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction
Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...
متن کاملEvaluation of Diameter Changes, Stress-strain Elastic Modulus and Stiffness in Normal and Atherosclerotic Common Carotid Arteries in Both Sex Based on End Pressure Variation
Evaluation of elastic properties of major arteries is subject of great interest with respect to the development of vascular diseases. In this study changes in diameter and cross-sectional area, stress-strain elastic modulus and stiffness of the common carotid arteries in healthy and atherosclerotic women and men were evaluated by using indirect end pressure changes. Variations in diameter and c...
متن کاملComparison of ultrasound and IV-DSA for carotid evaluation.
Sixty carotid bifurcations in 34 symptomatic patients were examined prospectively with ultrasound (continuous wave Doppler and high resolution, B-mode imaging) and intravenous digital subtraction angiography (IV-DSA). The overall quality of examination was better with DSA than with ultrasound. Imaging of the external carotid artery was particularly difficult with sonography. For evaluation of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
دوره 189 12 شماره
صفحات -
تاریخ انتشار 2017