Evaluation of a new Implicit Coupling Algorithm for the Partitioned Fluid-Structure Interaction Simulation of Bileaflet Mechanical Heart Valves

نویسندگان

  • Sebastiaan Annerel
  • Joris Degroote
  • Tom Claessens
  • Jan Vierendeels
چکیده

We present a newly developed Fluid-Structure Interaction coupling algorithm to simulate Bileaflet Mechanical Heart Valves dynamics in a partitioned way. The coupling iterations between the flow solver and the leaflet motion solver are accelerated by using the Jacobian with the derivatives of the pressure and viscous moments acting on the leaflets with respect to the leaflet acceleration. This Jacobian is used in the leaflet motion solver when new positions of the leaflets are computed during the coupling iterations. The Jacobian is numerically derived from the flow solver by applying leaflet perturbations. Instead of calculating this Jacobian every time step, the Jacobian is extrapolated from previous time steps and a recalculation of the Jacobian is only done when needed. The efficiency of our new algorithm is subsequently compared to existing algorithms which use fixed relaxation and dynamic Aitken Δ 2 relaxation in the coupling iterations when the new positions of the leaflets are computed. Results show that dynamic Aitken Δ 2 relaxation outperforms fixed relaxation. Moreover, during the opening phase of the valve, our new algorithm needs fewer subiterations per time step to achieve convergence than the method with Aitken Δ 2 relaxation. Thus, our newly developed FSI coupling scheme outperforms the existing coupling schemes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluid-Structure Interaction in the Cardiovascular System. Numerical Analysis and Simulation. (Interaction Fluide-Structure dans le Système Cardiovasculaire. Analyse Numérique et Simulation)

In this thesis we focus on the numerical analysis and the development of e cient partitioned algorithms for uid-structure interaction (FSI) problems arising in hemodynamics. In particular we consider the mechanical interaction of the blood with the large arteries, with the cardiac valves and with the myocardium. In partitioned FSI procedures the coupling between the uid and the structure can be...

متن کامل

Numerical simulation of a 3D Bileaflet Mechanical Heart Valve using Fluid-Structure Interaction

Because of their long life span and durability, Bileaflet Mechanical Heart Valves (BMHV) are preferred for valve replacement. However, current BMHV designs induce calcification and thromboembolism, which is believed to be due to non-physiological flow and turbulence generated by the valve leaflets. Therefore, numerical flow simulations can provide relevant information for design optimization [1...

متن کامل

Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach.

The main purpose of this study is to reproduce in silico the dynamics of a bileaflet mechanical heart valve (MHV; St Jude Hemodynamic Plus, 27mm characteristic size) by means of a fully implicit fluid-structure interaction (FSI) method, and experimentally validate the results using an ultrafast cinematographic technique. The computational model was constructed to realistically reproduce the bou...

متن کامل

Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.

The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional mode...

متن کامل

An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.

BACKGROUND AND AIM OF THE STUDY An integrated macro/micro approach was used to evaluate flow within the pivots of the Medtronic ADVANTAGE bileaflet heart valve. Results were compared with those obtained with the St. Jude Medical bileaflet heart valve. METHODS The integrated macro/micro approach consists of both a macroscopic hydrodynamic performance assessment and a three-part microscopic flo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010