Inspired oxygen concentrations in semiclosed circle absorber circuits with low flows of nitrous oxide and oxygen.
نویسنده
چکیده
Fresh gas flows of 1-5 l./min containing oxygen concentrations of 25-50% in nitrous oxide were led into a semiclosed circle absorber circuit. The resulting inspired oxygen concentrations were measured under conditions of spontaneous respiration. The lower the fresh gas flow, the greater was the discrepancy between fresh gas and inspired oxygen concentration. No association between minute volume and inspired oxygen concentration was seen. Measured value of inspired oxygen concentration agreed with those derived from the formulae of Mushin and Galloon (1960), and Fitton (1963), except at very low fresh gas flow. It appears possible to predict inspired oxygen concentration in a circle absorber circuit with low fresh gas flows of nitrous oxide and oxygen after a steady state of anaesthesia has been established.
منابع مشابه
An assessment of operating room environment air contamination with nitrous oxide and halothane and some scavenging methods.
This study was designed to assess operating room contamination with nitrous oxide and halothane when nitrous oxide 3 1/min and oxygen 2 1/min containing halothane one per cent were passed into a semiclosed circle absorber system from which the patients' lungs were ventilated with an Ohio ventimeter through a cuffed tracheal tube, with the exhaled gas vented to the floor. The normal room ventila...
متن کاملIsoflurane in a circle system with low gas flow.
Isoflurane was administered from a Goldman vaporizer to a circle breathing system with low fresh gas flows. The uptake and vapour concentration of isoflurane were compared in two groups of spontaneously breathing patients receiving oxygen alone (n = 19), or nitrous oxide and oxygen (n = 30). Anaesthesia was maintained successfully in all patients. The authors believe this to be a safe and econo...
متن کاملEffect of N2O on sevoflurane vaporizer settings during minimal- and low-flow anesthesia.
BACKGROUND Uptake of a second gas of a delivered gas mixture decreases the amount of carrier gas and potent inhaled anesthetic leaving the circle system through the pop-off valve. The authors hypothesized that the vaporizer settings required to maintain constant end-expired sevoflurane concentration (Etsevo) during minimal-flow anesthesia (MFA, fresh gas flow of 0.5 l/min) or low-flow anesthesi...
متن کاملThe measurement of gaseous exchange during nitrous oxide anaesthesia.
A method is described for the estimation of carbon dioxide output, oxygen uptake, and respiratory exchange ratio during nitrous oxide anaesthesia. The inspired and expired minute volumes are measured with a box-bag system, the carbon dioxide concentrations with a carbon dioxide sensitive electrode, and the oxygen concentrations with a polarograph. Carbon dioxide output can be measured with a co...
متن کاملFuzzy logic control of inspired isoflurane and oxygen concentrations using minimal flow anaesthesia.
In order to evaluate the performance of feedback fuzzy logic control of inspired oxygen and isoflurane concentrations, we studied 30 patients undergoing discectomy for lumbar (n = 26) or cervical (n = 4) disc herniation. Patients were allocated random to one of two groups: a standard group (n = 15) with low flow anaesthesia (1.2-1.3 litre min-1) and manual control of gas concentrations; and a f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 44 10 شماره
صفحات -
تاریخ انتشار 1972