IUD expulsion solved with implant technology.

نویسندگان

  • H Van Kets
  • D Wildemeersch
  • H van der Pas
  • M Vrijens
  • Y Van Trappen
  • W Delbarge
  • M Temmerman
  • I Batar
  • P Barri
  • F Martinez
چکیده

In an attempt to minimize the problem of IUD expulsion, implantation technology has been developed and tested. The trials have extended from 1985 until the present time for interval as well as for immediate postabortal and post-placental insertion and fixation of the CuFix IUD (Gyne-Fix). The present article reports on an ongoing study with GyneFix interval insertion, with an improved inserter, in 820 women, observed up to 3 years, of whom 213 (25.9%) are nulligravid/nulliparous. The cumulative expulsion rate is 0.6 per 100 women-years at 3 years and is not significantly higher in the nulligravid/nulliparous group. The cumulative pregnancy rate is 0.6 and the cumulative removal rate for medical reasons 3.2 at 3 years. The total experience in this multicenter study covers approximately 14,000 woman-months. It is concluded that the design characteristics of the GyneFix (fixed, frameless, and flexible) explain the low expulsion, high efficacy and high acceptability rates. The implantation technology is very effective and the improved inserter allows easy insertion and optimal anchoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate postplacental insertion of a copper intrauterine device: a pilot study to evaluate expulsion rate by mode of delivery.

BACKGROUND The present study aimed to investigate risk factors for expulsion in immediate postplacental IUD insertion. We specifically sought to determine whether cesarean delivery before or during labor have an impact on IUD expulsion. METHODS The study included 160 pregnant women for immediate IUD insertion following vaginal or cesarean delivery. Three groups of patients were recruited: Pat...

متن کامل

Partial and complete expulsion of the Multiload 375 IUD and the levonorgestrel-releasing IUD after correct insertion.

OBJECTIVE The contraceptive efficacy of intrauterine devices (IUD) is thought to relate to the position of the IUD in the uterine cavity. Several trials examined the number of copper IUD expulsions, but none evaluated the partial and complete expulsion rate of the levonorgestrel-releasing device (LNG-IUD). STUDY DESIGN This retrospective cohort study compares the dislocation rate of the Multi...

متن کامل

Role of uterine forces in intrauterine device embedment, perforation, and expulsion

BACKGROUND The purpose of this study was to examine factors that could help reduce primary perforation during insertion of a framed intrauterine device (IUD) and to determine factors that contribute in generating enough uterine muscle force to cause embedment and secondary perforation of an IUD. The objective was also to evaluate the main underlying mechanism of IUD expulsion. METHODS We comp...

متن کامل

A 3-year multicentre randomized controlled trial of etonogestrel- and levonorgestrel-releasing contraceptive implants, with non-randomized matched copper-intrauterine device controls.

STUDY QUESTION Is there any difference in the clinical performance of the 3-year one-rod etonogestrel (ENG)- and the 5-year two-rod levonorgestrel (LNG)-releasing contraceptive implants during 3 years of insertion, and between implant and intrauterine device (IUD) contraception, in particular complaints possibly related to hormonal contraceptives? SUMMARY ANSWER The cumulative contraceptive e...

متن کامل

Expulsion and continuation rates after postabortion insertion of framed IUDs versus frameless IUDs – review of the literature

Background Early intrauterine device (IUD) discontinuation after insertion immediately following aspiration abortion or after early medical abortion occurs as a consequence of expulsion of the IUD or removal due to side effects. These are often the consequence of the uterine forces impacting on the IUD due to spatial discrepancy with the uterine cavity causing pain, abnormal bleeding, and event...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contraception

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 1995