Design, characterisation and in vivo testing of a new, adjustable stiffness, external fixator for the rat femur.

نویسندگان

  • V Glatt
  • C H Evans
  • R Matthys
چکیده

Very little is known about the influence of the mechanical environment on the healing of large segmental defects. This partly reflects the lack of standardised, well characterised technologies to enable such studies. Here we report the design, construction and characterisation of a novel external fixator for use in conjunction with rat femoral defects. This device not only imposes a predetermined axial stiffness on the lesion, but also enables the stiffness to be changed during the healing process. The main frame of the fixator consists of polyethylethylketone with titanium alloy mounting pins. The stiffness of the fixator is determined by interchangeable connection elements of different thicknesses. Fixators were shown to stabilise 5 mm femoral defects in rats in vivo for at least 8 weeks during unrestricted cage activity. No distortion or infections, including pin infections, were noted. The healing process was simulated in vitro by inserting into a 5 mm femoral defect, materials whose Young's moduli approximated those of the different tissues present in regenerating bone. These studies confirmed that, although the external fixator is the major determinant of axial stiffness during the early phase of healing, the regenerate within the lesion subsequently dominates this property. There is much clinical interest in altering the mechanics of the defect to enhance bone healing. Our data suggest that, if alteration of the mechanical environment is to be used to modulate the healing of large segmental defects, this needs to be performed before the tissue properties become dominant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adjustable stiffness, external fixator for the rat femur osteotomy and segmental bone defect models.

The mechanical environment around the healing of broken bone is very important as it determines the way the fracture will heal. Over the past decade there has been great clinical interest in improving bone healing by altering the mechanical environment through the fixation stability around the lesion. One constraint of preclinical animal research in this area is the lack of experimental control...

متن کامل

Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study

BACKGROUND Locking compress plate, as external fixator, is an attractive technique for distal tibial fracture treatment. But it still remains unclear whether the external LCP has sufficient stiffness. Thus, the present study aims to make a comprehensive evaluation of the stiffness of external locking compress plate when it is used as an external fixator in distal tibial fractures treatment. M...

متن کامل

Modulation of fixation stiffness from flexible to stiff in a rat model of bone healing

Background and purpose - Constant fixator stiffness for the duration of healing may not provide suitable mechanical conditions for all stages of bone repair. We therefore investigated the influence of stiffening fixation on callus stiffness and morphology in a rat diaphyseal osteotomy model to determine whether healing time was shortened and callus stiffness increased through modulation of fixa...

متن کامل

Characterization of interfragmentary motion associated with common osteosynthesis devices for rat fracture healing studies

Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been es...

متن کامل

FE parametric analysis of nonlinear mechanical behaviour of Ilizarov external fixator

The study describes a computational approach for predicting the mechanical response of different configurations of the Ilizarov external fixation system. The Ilizarov type fixators are now being used to an increasing extend to stabilize bone fractures and for limb lengthtening [5,6] and its functions are investigated using numerical [e.g. 3,7] and experimental [e.g. 1,2] techniques. The device ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European cells & materials

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2012