CCD Imaging Data with a Dome Flat Field System

نویسندگان

  • J. L. Marshall
  • D. L. DePoy
چکیده

We describe the flattening of scientific CCD imaging data using a dome flat field system. The system uses light emitting diodes (LEDs) to illuminate a carefully constructed dome flat field screen. LEDs have several advantages over more traditional illumination sources: they are available in a wide range of output wavelengths, are inexpensive, have a very long source lifetime, and are straightforward to control digitally. The circular dome screen is made of a material with Lambertian scattering properties that efficiently reflects light of a wide range of wavelengths and incident angles. We compare flat fields obtained using this new system with two types of traditionally-constructed flat fields: twilight sky flats and nighttime sky flats. Using photometric standard stars as illumination sources, we test the quality of each flat field by applying it to a set of standard star observations. We find that the dome flat field system produces flat fields that are superior to twilight or nighttime sky flats, particularly for photometric calibration. We note that a ratio of the twilight sky flat to the nighttime sky flat is flat to within the expected uncertainty; but since both of these flat fields are inferior to the dome flat, this common test is not an appropriate metric for testing a flat field. Rather, the only feasible and correct method for determining the appropriateness of a flat field is to use standard stars to measure the reproducibility of known magnitudes across the detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image Quality of Digital Direct Flat-Panel Mammography Versus an Indirect Small-Field CCD Technique Using a High-Contrast Phantom

OBJECTIVE To compare the detection of microcalcifications on mammograms of an anthropomorphic breast phantom acquired by a direct digital flat-panel detector mammography system (FPM) versus a stereotactic breast biopsy system utilizing CCD (charge-coupled device) technology with either a 1024 or 512 acquisition matrix (1024 CCD and 512 CCD). MATERIALS AND METHODS Randomly distributed silica b...

متن کامل

The Jay Baum Rich telescope: a Centurion 28 at the Wise Observatory

We describe the third telescope of the Wise Observatory, a 0.70-m Centurion 28 (C28IL) installed in 2013 and named the Jay Baum Rich telescope to enhance significantly the wide-field imaging possibilities of the observatory. The telescope operates from a 5.5-m diameter dome and is equipped with a large-format red-sensitive CCD camera, offering a ∼one square degree imaged field sampled at 0′′.83...

متن کامل

Flat Fields for the Ccd Spectral Modes

Except for fringing effects at the longer wavelengths, the pixel-to-pixel flat field for the spectral modes is independent of wavelength but does change with time. An average flat with one to four million electrons/px is applicable to all CCD first order modes, except G750M, after the dust mote regions are inserted from separate low or medium dispersion flats. Application of this flat to spectr...

متن کامل

STIS CCD spectroscopic P-flats

The analysis of the cycle 17 STIS CCD spectroscopic flats (Niemi 2010) pointed to the need to create a new dust mote image for the low resolution grating (L-mode) P-flats. This ISR describes the creation of the new L-mode P-flat from low resolution exposures taken during cycles 18 and 19. The document also analyzes the time dependence of the dust mote images as well as that of the intrinsic fla...

متن کامل

Development of a Protocol for CCD Calibration: Application to a Multispectral Imaging System

In this paper we describe in detail a method for calibrating a CCD-based camera. The calibration aims to remove both temporal and systematic noises introduced by the sensor, electronics, and optics after which we can correct the non-linearity of its response. For the non-linearity correction we use a simple and powerful approach consisting on a complementary approach between a polynomial fittin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005