A prospective randomised controlled trial of the Kiwi Omnicup versus conventional ventouse cups for vacuum-assisted vaginal delivery.

نویسنده

  • H Senanayake
چکیده

OBJECTIVE To evaluate the performance and safety of the Kiwi Omnicup and compare it to conventional vacuum cups in routine clinical practice. DESIGN A randomised controlled trial of the Kiwi Omnicup versus conventional vacuum cups. SETTING Queen Charlotte's and Chelsea Hospital, a tertiary referral hospital in London from April 2001 to March 2004. POPULATION Women requiring assisted vaginal delivery by ventouse. METHODS Women were randomised to the Kiwi Omnicup (n=206) or conventional vacuum cups (n=198). Data regarding maternal demographics, labour, mode of delivery and maternal and neonatal outcome were collected. MAIN OUTCOME MEASURES Failure of delivery with instrument of first choice. RESULTS The Kiwi Omnicup was less successful at delivery with instrument of first choice than the conventional ventouse, failure rate 30.1 versus 19.2% (RR 1.58; 95% CI 1.10-2.24). It was associated with a greater number of cup detachments (mean 0.68 compared with 0.28, with 44% compared with 18% having at least one detachment [P<0.0001]). There was no difference in the incidence of severe maternal trauma, and there were no cases of serious neonatal injury. CONCLUSIONS The Kiwi Omnicup is less successful than conventional ventouse in achieving vaginal delivery, but its safety profile is comparable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decreased neonatal pain response after vaginal-operative delivery with Kiwi OmniCup versus metal ventouse

BACKGROUND Vaginal delivery, especially operative assisted vaginal delivery, seems to be a major stressor for the neonate. The objective of this study was to evaluate the stress response after metal cup versus Kiwi Omnicup® ventouse delivery. METHODS The study was a secondary observational analysis of data from a former prospective randomised placebo controlled multicentre study on the analge...

متن کامل

Operative vaginal delivery: clinical appraisal of a new vacuum extraction device.

The efficacy of a new vacuum extraction device, the Kiwi OmniCup, and its effects on mothers and infants were tested in a study of 18 non-rotational and 32 rotational vacuum assisted deliveries. Forty-nine (98%) of the extractions resulted in successful vaginal births. Autorotation of the fetal head when the occiput was transverse or posterior was achieved in 31 (97%) of the 32 vacuum procedure...

متن کامل

Comparison of Obstetric Efficacy and Safety of the Kiwi OmniCup with Conventional Vacuum Extraction Vergleich der geburtshilflichen Effektivität und Sicherheit des Kiwi OmniCup mit der konventionellen Vakuumextraktion

Purpose: The aim of the present study was to compare the safety and efficacy of the Kiwi OmniCup system with conventional vacuum delivery. Methods: A retrospective study of operative vaginal deliveries was done for 4682 births. The procedures included 217 operative vaginal deliveries (4.6%), 79 of which were done using conventional vacuum extraction (37%) and 138 using the Kiwi system (63%). Re...

متن کامل

Commentary on 'Maternal and child health after assisted vaginal delivery: five-year follow up of a randomised controlled study comparing forceps and ventouse'.

OBJECTIVE To undertake a five year follow up of a cohort of women and children delivered by forceps or vacuum extractor in a randomised controlled study. DESIGN Follow up of a randomised controlled trial. SETTING District general hospital in the West Midlands. POPULATION Follow up questionnaires were sent to 306 of the 313 women originally recruited at the North Staffordshire Hospital to ...

متن کامل

Vacuum-assisted delivery: an analysis of traction force and maternal and neonatal outcomes.

Safety recommendations for vacuum-assisted delivery focus on limiting the number of pulls and the duration of the procedure. With the introduction of the Kiwi OmniCup vacuum extractor incorporating a Traction Force Indicator, it is now possible to reliably monitor and control the amount of traction force exerted on the fetal scalp. The OmniCup was used in a prospective observational study of 11...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BJOG : an international journal of obstetrics and gynaecology

دوره 113 2  شماره 

صفحات  -

تاریخ انتشار 2006