A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
نویسندگان
چکیده
PURPOSE Tomotherapy for intensity-modulated radiation has been demonstrated to reduce unnecessary irradiations to adjacent organs at risk (OARs). The purpose of this study was to compare the dosimetric parameters between Tomotherapy and three-dimensional conformal radiotherapy (3D-CRT) in rectal cancer patients. MATERIALS AND METHODS We redesigned three-dimensional conformal plans for 20 rectal cancer patients who had received short-course preoperative radiotherapy with Tomotherapy. The target coverage for 3D-CRT and Tomotherapy was evaluated with the following including the mean dose, V(nGy), D(min), D(max), radiation conformality index (RCI), and radical dose homogeneity index (rDHI). RESULTS The mean PTV dose for Tomotherapy is significantly higher than that observed for the 3D-CRT (p = 0.043). However, there is no significant difference in the V(23.25Gy), V(26.25Gy), V(27.5Gy), and RCI values between Tomotherapy and 3D-CRT. However, the average rDHI (p < 0.001) value for Tomotherapy was significantly lower than that reported for the 3D-CRT. Tomotherapy significantly lowered the mean level of irradiation doses to the bladder, small bowel, and femur heads as compared to 3D-CRT. CONCLUSIONS Tomotherapy could produce a favorable target coverage and significant dose reduction for the OARs at the expense of acceptable dose inhomogeneity of the PTV compared with 3D-CRT in rectal cancer patients.
منابع مشابه
Dosimetric evaluation of Tomotherapy and four-box field conformal radiotherapy in locally advanced rectal cancer
PURPOSE To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. MATERIALS AND METHODS Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvi...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملRespiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.
Introduction: The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer. Materials and Methods: Two CT scan was performred for each pati...
متن کاملEffect of Bolus Frequency and Its Thickness in Postmastectomy Three-dimensional Conformal Radiotherapy on Skin Dose for Superposition Algorithm
Introduction: The postmastectomy radiotherapy uses bolus to improve the coverage close to the skin; however, it needs to be removed in case of severe skin toxicity. This study investigated the effect of bolus parameters (i.e., frequency and thickness) for the superposition algorithm on skin dose in postmastectomy three-dimensional conformal radiotherapy (3D-CRT). <str...
متن کاملDosimetric Study of Tissue Heterogeneity Correction for Breast Conformal Radiotherapy
Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...
متن کامل