Quality Control and Patient Dosimetry on line for Computed Tomography
نویسندگان
چکیده
The aim of this work is to present the functionalities and first results of an automatic system on quality control and patient dosimetry for diagnostic radiology, and its application to computed tomography (CT) in a big university hospital. The system is directly connected to the PACS (Picture Archive an Communication System) of the hospital and extracts useful information contained in the DICOM headers and Radiation Dose Structured Reports (RDSRs). The full process is automatic and was tested during the past 6 months for 11,500 procedures in three CT units. The system allows not only to extract, archive and process the parameters contained in the DICOM headers and RDSRs, but also to manage all the additional information contained in such headers for a quality control "on line". With all this information, several trigger conditions can be implemented to generate alarms and to launch corrective actions in cases such as individual dose values per examination higher than 3 times the diagnostic reference level (DRL), median values of the last 30 procedures higher than the DRL, etc. For other modalities, trigger conditions like low compression in mammography or low kV in chest images can also be used. The system allows export of data for statistical process. A personal patient dose record can be built, initially limited to the examinations performed at the hospital, but with the capability of further connection with other hospitals and outpatient centers using the same system. Mean and median Dose Length Product (DLP) values for the most common CT procedures are presented and compared with the existing references available, to decide if optimization actions are required to refine some clinical protocols. Effective doses have also been estimated from the DLP values, using the conversion factors based on the current Dose Datamed European Guidelines.
منابع مشابه
Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملDosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography
Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملEffect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations
Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...