Analysis of Propane Thermal State in Underground Tanks Taking Into Consideration Design Issues
نویسندگان
چکیده
Preliminary note The paper presents an analysis of annual variations of temperature and the corresponding saturation pressure of saturated liquid propane in a mounded cylindrical tank used for liquefied petroleum gas (LPG) storage. A mathematical model has been established based on a finite volume method. Boundary and initial conditions have been assumed for the Croatian climate. Simulations have been performed using the commercial CFD (Computational Fluid Dynamic) code on the representative numerical example. Analysis results have been presented through diagrams. It has been pointed out that the present regulation and practice for such tanks defines too high a design pressure of 1.64 MPa for the Croatian climate and that pressure of 1.2 MPa is sufficient to ensure proper design of such vessels. Significant simplifications and savings in production process can be achieved by changing the unnecessarily high design pressure.
منابع مشابه
Numerical Analysis of the Seismic Response of Underground Steel Storage Tanks
The seismic behaviour of underground structures is generally satisfactory compared to the above-ground ones. However, despite of the buried structure confinement, in recent strong seismic events some underground structure as tunnels, pipelines and tanks suffered high damage; for this reason, a strong effort is focused to evaluate the seismic vulnerability of these structure and to give codes in...
متن کاملSolid state synthesis of NiO nanoparticles from [(1,2-bis(2-formyl-3-methoxyphenyl)propane)nickel(II)] chloride
In this paper, nickel oxide (NiO) nanoparticles have been prepared by solid state thermal decomposition of an acyclic nickel(II) complex (1,2-bis(2-formyl-3-methoxyphenyl)propane)nickel(II) chloride, [NiL]Cl2, in an electrical furnace at optimal temperature, 450 ºC for 3.5 h. The nickel(II) complex is obtained via solid state synthesis using nickel(II) chloride and tetradentate O4 acyclic ligan...
متن کاملRetroactive Liability and Future Risk: The Optimal Regulation of Underground Storage Tanks
The optimal design of environmental liability policy focuses on two primary policy issues: the cleanup of existing sources of pollution and the definition and enforcement of policies to promote prospectively efficient environmental risk reduction. Through the analysis of a policy toward a pervasive environmental risk -leaking underground storage tanks -we analyze the effectiveness of an existin...
متن کاملInsights from the Risk Analysis of a Nearby Propane Tank Farm
Due to the flammability and explosion characteristics of the propane vapor cloud, a nearby propane tank farm could possibly present a significant risk to the operation of nuclear power plants. Accidental releases of propane may occur in the propane supply pipeline, at the propane storage tanks, or on the propane transportation routes due to propane transport trailer truck accidents. Loss of con...
متن کاملRole of Environmental Simulation at the Early Stage of Design in Order to Achieve Outdoor Thermal Comfort: A Case Study of Ekbatan and Apadana Residential Complexes in Tehran, Iran
Outdoor environment and its requirement are one of the crucial issues of the designer especially in the residential complexes .early stage simulation is a method which is considered in many studies and projects to demonstrate and predict the environmental performance of the buildings. Therefore in this study to assess the importance of the early-stage environmental consideration through simulat...
متن کامل