Reduction in retake rates and radiation dosage through computed radiography.

نویسندگان

  • N Polunin
  • T A Lim
  • K P Tan
چکیده

The availability of computed radiography has opened the possibility of using reduced dosage for radiographs in clinical settings and reducing the retake rate. A prospective controlled study was carried out over a period of four months comparing conventional X-rays and computed radiography. The aim was to assess if computed radiography at 50% normal dosage would result in films of adequate quality and a reduced retake rate compared to conventional radiography. The number and reason for retakes in each group were recorded. Film quality comparison using only chest X-rays (CXR) in one of three positions; erect posterior-anterior (PA), anterior-posterior (AP) sitting and supine was done by a panel of radiologists. A total of 6373 conventional and 4127 digital films were analysed. The overall retake rate was lower in the computed radiography group (4.6 vs 8.2% P < 0.001) as was the retake rate due to exposure factors (0.6% vs 3.2% P < 0.01). There was a higher proportion of optimal films in the computed radiography group for erect PA and sitting AP CXR (71% vs 61% P = 0.0015 and 64% vs 9% P = 0.0009 respectively) but no difference for supine films. Computed radiography resulted in a reduced retake rate due to exposure factors leading to a reduction in the overall retake rate. Despite 50% dosage reduction, films were of better or equal quality when compared to conventional radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Reduction Methods in Chest Computed Tomography

Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Repeat analysis program in radiology departments in Mazandaran province- Iran Impact on population radiation dose

Background: The rejected films in radiography may be responsible for an unnecessary increase in the radiation dose to the population. The effective dose to population is a very important factor in estimation of stochastic risk in radiology. The main goal of this study was to determine the effective dose to members of the public due to rejected films in diagnostic radiology departments in the No...

متن کامل

Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran

Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 1998