Numerical simulations of canine retraction with T-loop springs based on the updated moment-to-force ratio.
نویسندگان
چکیده
The purpose of this study was to develop a new finite element method for simulating long-term tooth movements and to compare the movement process occurring in canine retraction using a T-loop spring having large bends and with that having small bends. Orthodontic tooth movement was assumed to occur in the same manner as the initial tooth movement, which was controlled by the moment-to-force (M/F) ratios acting on the tooth. The M/F ratios were calculated as the reaction forces from the spring ends. For these M/F ratios, the teeth were moved based on the initial tooth movements, which were calculated by using the bilinear elastic model of the periodontal ligament. Repeating these calculations, the teeth were moved step by step while updating the M/F ratio. In the spring with large bends, the canine at first moved bodily, followed by root distal tipping. The bodily movement was quickly achieved, but over a short distance. In the spring with small bends, the canine at first rotated and root mesial tipping occurred, subsequently the canine uprighted and the rotation decreased. After a long time elapsed, the canine moved bodily over a long distance. It was found that the long-term tooth movement produced by the T-loop springs could be simulated by the method proposed in this study. The force system acting on the teeth and the movement type remarkably changed during the long-term tooth movement. The spring with large bends could move the canine bodily faster than that with small bends.
منابع مشابه
Auxiliary springs in continuous arch treatment: Part 2. Appliance use and case reports.
In the second part of this series, three clinical examples are presented to illustrate the use of auxiliary space-closure springs with clinically manageable moment-to-force ratios and new canine brackets to accommodate these springs within the framework of conventional and straight-wire 0.018-inch appliance systems. Eligiloy retraction spring models (0.1650 inch x 0.02150 inch) in the edgewise ...
متن کاملA numerical simulation of orthodontic tooth movement produced by a canine retraction spring.
Tooth movements produced by a canine retraction spring were calculated. Although a gable bend and an anti-rotational bend were incorporated into the spring, the canine tipped and rotated initially. Retraction force decreased and moment-to-force ratio increased after the spring legs closed. Then, the initial tipping and rotation began to be corrected. As a result, the canine moved almost bodily ...
متن کاملEvaluating the Amount of Tooth Movement and Root Resorption during Canine Retraction with Friction versus Frictionless Mechanics Using Cone Beam Computed Tomography
BACKGROUND The current study was carried out to compare the amount of tooth movement during canine retraction comparing two different retraction mechanics; friction mechanics represented by a NiTi closed coil spring versus frictionless mechanics represented by T - loop, and their effect on root resorption using Cone Beam Computed Tomography (CBCT). METHOD Ten patients were selected in a split...
متن کاملEffect of Segmental Joint on Internal Forces in Tunnel Lining under Seismic Loading by Numerical Method
Although segmental tunnel linings are often used for seismic areas, the influence of segment joints on the segmental lining behavior under seismic loading has not been thoroughly considered in the literature. This paper presents the results of a numerical study investigating the effects of the rotational, axial, and radial joint stiffness of the longitudinal joints on the structural force...
متن کاملLactate Dehydrogenase Activity in Gingival Crevicular Fluid as a Marker in Orthodontic Tooth Movement
OBJECTIVES This study aims at analyzing the changes in gingival crevicular fluid (GCF) lactate dehydrogenase (LDH) activity during orthodontic movement. METHODS Twenty patients all requiring first premolar extractions were selected and treated with conventional straight wire mechanotherapy. Canine retraction was done using 125 g Nitinol closed coil springs. The maxillary canine on one side se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 34 1 شماره
صفحات -
تاریخ انتشار 2012