Development of a new laser-line and CCD based optical-CT scanner for the readout of 3D radiation dosimeters
نویسندگان
چکیده
We present initial results on the comparison of the dose readout from a three dimensional polymer gel dosimeter using two different optical-CT systems; i) a common wide field and a wide area detector optical-CT system and ii) a new ‘laser-line’ and wide area detector based optical-CT system. The findings presented herein highlight the advantage of the laser based over the wide field optical-CT concept for the readout of scattering 3D dosimeters. Moreover, the new ‘laser-line’ based optical-CT system overcomes the disadvantage of the long acquisition times required by the existing laser-based instruments.
منابع مشابه
Designing and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملFan-beam scanning laser optical CT system for large volume 3D dosimetry
Introduction: Optical CT scanning of radiochromic gel dosimeters is a method for true 3D dosimetry, which is becoming increasingly needed as radiation therapy techniques become more advanced. Optical CT has developed from slow pencil beam laser scanners to fast cone-beam scanners using cameras. However, scattered light perturbs these broad-beam scanners, resulting in cupping artifacts and loss ...
متن کاملUncertainty in 3D gel dosimetry
Three-dimensional (3D) gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as the technique can cover the full treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. It can also be applied to benchmark new treatment strategies such as image guided and tracking radiotherapy techniques. A major obstacle that has hin...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملTrue 3D chemical dosimetry (gels, plastics): Development and clinical role
Since the introduction of volumetric chemical dosimetry with Fricke gel dosimeters in the 1980s, three-dimensional (3D) dosimetry has been a promising technique for the clinic, since it provides a unique methodology for 3D dose measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. In the last decad...
متن کامل