Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?
نویسندگان
چکیده
BACKGROUND AND PURPOSE There is considerable controversy about the treatment of complex, displaced proximal humeral fractures. Various types of head-preserving osteosynthesis have been suggested. This prospective case series was designed to evaluate the perioperative and early postoperative complications associated with fixed-angle implants and to record outcome after bone healing. PATIENTS AND METHODS Fractures of the proximal humerus were stabilized surgically in 87 patients (mean age 64 (16-93) years) by application of a fixed-angle plate (65 PHILOS, 22 T-LCP). There were 34 2-segment fractures, 42 3-segment fractures, and 11 4-segment fractures, including 7 dislocation fractures. Follow-up assessment after a minimum of 12 months was based on the Constant, UCLA, and DASH scores and on radiographs. RESULTS Postoperative complications included soft tissue problems (n = 9), humeral head necrosis (n = 9), screw perforation (n = 11), secondary displacements (n = 14), and delayed fracture healing (n = 4). Treatment outcomes recorded on the various scores were very good in 60-82% of the cases. INTERPRETATION Screw perforation of fixed-angle implants has replaced the complications of secondary displacement and implant loosening after using conventional plates. Even with the use of fixed-angle implants, fractures of the proximal humerus are associated with a high complication rate and sometimes poor outcome.
منابع مشابه
Biomechanical Analysis of Nail and Plate Osteosynthesis for the Humerus Fracture
SCIENTIFIC PROBLEM Fractures of the proximal humerus are one of the most common type of fractures. In particular, elderly people are affected due to loss of bone density, i.e. osteoporosis. Biological, anatomical and biomechanical aspects influence the clinical functional results of the operative therapy. For the operative therapy, different osteosynthesis techniques are known. In the last few ...
متن کاملOsteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results
UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...
متن کاملHemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
BACKGROUND The optimal surgical management of dislocated three- and four-part fractures of the proximal humerus in elderly patients remains unclear. Most used techniques are hemiarthroplasty and angle-stable locking compression plate osteosynthesis. In the current literature there is no evidence available presenting superior results between hemiarthroplasty and angle-stable locking compression ...
متن کاملReduction of postoperative bleeding following operative treatment of proximal humerus fractures using a collagen sponge
Aim of the present study is to investigate the efficacy and safety of TachoSil to reduce afterbleeding and hematoma following operative treatment of proximal humerus fractures. In a prospective randomized study we included a consecutive series of 40 patients with a proximal humeral fracture in this study. All fractures were stabilized surgically with a fixed-angle “Philos plate” from May 2008 t...
متن کاملComputer representation of osteosynthesis stability in locking plates used for the treatment of osteoporotic proximal humerus fractures.
BACKGROUND Proximal humerus fractures are represented as 4-5% of all fractures, with incidence notably growing with age. Since surgical internal fixation in treatment of proximal humeral fractures is used, fractures of osteoporotic bone and choice of plate for their osteosynthesis represent particular problem. The aim of the study was to test two locking plates: Philos plate with locking screws...
متن کامل