A time-frequency domain approach of heart rate estimation from photoplethysmographic (PPG) signal

نویسندگان

  • Mohammad Tariqul Islam
  • Ishmam Zabir
  • Sk. Tanvir Ahamed
  • Md. Tahmid Yasar
  • Celia Shahnaz
  • Shaikh Anowarul Fattah
چکیده

ObjectiveHeart rate monitoring using wrist type Photoplethysmographic (PPG) signals is getting popularity because of construction simplicity and low cost of wearable devices. The task becomes very difficult due to the presence of various motion artifacts. The objective is to develop algorithms to reduce the effect of motion artifacts and thus obtain accurate heart rate estimation. MethodsProposed heart rate estimation scheme utilizes both time and frequency domain analyses. Unlike conventional single stage adaptive filter, multi-stage cascaded adaptive filtering is introduced by using three channel accelerometer data to reduce the effect of motion artifacts. Both recursive least squares (RLS) and least mean squares (LMS) adaptive filters are tested. Moreover, singular spectrum analysis (SSA) is employed to obtain improved spectral peak tracking. The outputs from the filter block and SSA operation are logically combined and used for spectral domain heart rate estimation. Finally, a tracking algorithm is incorporated considering neighbouring estimates. ResultsThe proposed method provides an average absolute error of 1.16 beat per minute (BPM) with a standard deviation of 1.74 BPM while tested on publicly available database consisting of recordings from 12 subjects during physical activities. ConclusionIt is found that the proposed method provides consistently better heart rate estimation performance in comparison to that recently reported by TROIKA, JOSS and SPECTRAP methods. SignificanceThe proposed method offers very low estimation error and a smooth heart rate tracking with simple algorithmic approach and thus feasible for implementing in wearable devices to monitor heart rate for fitness and clinical purpose.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise: an approach based on adaptive filtering.

Photoplethysmographic (PPG) signals are easily corrupted by motion artifacts when the subjects perform physical exercise. This paper introduces a two-step processing scheme to estimate heart rate (HR) from wrist-type PPG signals strongly corrupted by motion artifacts. Adaptive noise cancellation, using normalized least-mean-square algorithm, is first performed to attenuate motion artifacts and ...

متن کامل

Cross Time-Frequency Analysis for Combining Information of Several Sources: Application to Estimation of Spontaneous Respiratory Rate from Photoplethysmography

A methodology that combines information from several nonstationary biological signals is presented. This methodology is based on time-frequency coherence, that quantifies the similarity of two signals in the time-frequency domain. A cross time-frequency analysis method, based on quadratic time-frequency distribution, has been used for combining information of several nonstationary biomedical si...

متن کامل

TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic (PPG) Signals During Intensive Physical Exercise

Heart rate monitoring using wrist-type photoplethysmographic (PPG) signals during subjects’ intensive exercise is a difficult problem, since the signals are contaminated by extremely strong motion artifacts caused by subjects’ hand movements. So far few works have studied this problem. In this work, a general framework, termed TROIKA, is proposed, which consists of signal decomposiTion for deno...

متن کامل

Cascade and parallel combination (CPC) of adaptive filters for estimating heart rate during intensive physical exercise from photoplethysmographic signal

Photoplethysmographic (PPG) signal is getting popularity for monitoring heart rate in wearable devices because of simplicity of construction and low cost of the sensor. The task becomes very difficult due to the presence of various motion artefacts. In this study, an algorithm based on cascade and parallel combination (CPC) of adaptive filters is proposed in order to reduce the effect of motion...

متن کامل

A preliminary attempt to understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability

In this study, we investigated the difference between heart rate variability (HRV) derived from electrocardiogramic(ECG) signals and pulse rate variability (PRV) derived from photoplethysmographic(PPG) signals. Fourteen healthy subjects conducted the protocol: 10 min physiological signals including distal pulse wave on finger and ear from photoplethysmography (PPG), and heart beat from electroc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomed. Signal Proc. and Control

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2017