Effective methods of in-line intravenous fluid warming at low to moderate infusion rates.
نویسنده
چکیده
Three methods of warming intravenous (IV) fluids were examined. An in-line blood warmer was generally ineffective at flow rates of < 250 mL/hr but did produce temperatures of 30 to 31 degrees C at the catheter when the infusion rate was 500 to 1,000 mL/hr and the tubing was insulated. An in-line hot water bath produced temperatures of > or = 30 degrees C at flow rates of 200 to 1,000 mL/hr with uninsulated tubing. The addition of insulation maintained on infusate temperature of > or = 30 degrees C at a rate of 100 mL/hr. Application of a K-Thermia pad to the IV tubing close to the patient maintained an infusate temperature of > or = 30 degrees C at rates of 50 to 200 mL/hr. Warming at rates of 200 to 1,000 mL/hr is most effective with an in-line hot water bath. Warming at low infusion rates is best accomplished with a K-Thermia pad. The use of in-line blood warmers for routine fluid warming is ineffective.
منابع مشابه
Mega Acer Kit® is more effective for warming the intravenous fluid than Ranger™ and ThermoSens® at 440 ml/h of infusion rate: an experimental performance study
BACKGROUND Few studies have investigated the effectiveness of intravenous fluid warmers at low and moderate flow rates below 1,000 ml/h. In this study, we compared the effectiveness of three different fluid warmers at a low flow rate (440 ml/h). METHODS We experimentally investigated the fluid warming performances of Mega Acer Kit® (Group M, n = 10), Ranger™ (Group R, n = 10), and ThermoSens®...
متن کاملAn experimental study of warming intravenous fluid in a cold environment.
OBJECTIVE Numerous studies support the use of warmed intravenous fluids in hypothermic patients. The most effective method to accomplish this goal in a cold prehospital, wilderness, or combat setting is unknown. We evaluated various methods of warming intravenous fluids for a bolus infusion in a cold remote environment. METHODS One liter and 500 mL bags of intravenous fluid at 5 degrees C wer...
متن کاملCerebral blood flow and intracranial pressure in the dog during intravenous infusion of nitroglycerin alone and in combination with dopamine.
Nitroglycerin, long known as a safe and effective dilator of the large coronary arteries, has recently been shown to dilate the basilar artery of the dog after experimentally induced vasospasm. In this study we have evaluated the effects of intravenous nitroglycerin on local cerebral blood flow (H2 clearance technique) and intracranial pressure (intracisternal needle monitor) in normal beagle d...
متن کاملA prospective evaluation of the contribution of ambient temperatures and transport times on infrared thermometry readings of intravenous fluids utilized in EMS patients
BACKGROUND During cold weather months in much of the country, the temperatures in which prehospital care is delivered creates the potential for inadvertently cool intravenous fluids to be administered to patients during their transport and care by emergency medical services (EMS). There is some potential for patient harm from unintentional infusion of cool intravenous fluids. Prehospital provid...
متن کاملThe effect of infusion rate and catheter length on the temperature of warming fluid
BACKGROUND We used warming fluid for maintenance of body temperature in operating room or intensive care unit. This study was aimed to investigate the effect of infusion rate and catheter length on the temperature of warming fluid. METHODS Normal saline was used for testing infusion and temperature of infusion was maintained by a warmer as 40. The temperatures of solution in infusion line wer...