Molecular mass ranges of coal tar pitch fractions by mass spectrometry and size-exclusion chromatography.

نویسندگان

  • F Karaca
  • T J Morgan
  • A George
  • I D Bull
  • A A Herod
  • M Millan
  • R Kandiyoti
چکیده

A coal tar pitch was fractionated by solvent solubility into heptane-solubles, heptane-insoluble/toluene-solubles (asphaltenes), and toluene-insolubles (preasphaltenes). The aim of the work was to compare the mass ranges of the different fractions by several different techniques. Thermogravimetric analysis, size-exclusion chromatography (SEC) and UV-fluorescence spectroscopy showed distinct differences between the three fractions in terms of volatility, molecular size ranges and the aromatic chromophore sizes present. The mass spectrometric methods used were gas chromatography/mass spectrometry (GC/MS), pyrolysis/GC/MS, electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) and laser desorption time-of-flight mass spectrometry (LD-TOFMS). The first three techniques gave good mass spectra only for the heptane-soluble fraction. Only LDMS gave signals from the toluene-insolubles, indicating that the molecules were too involatile for GC and too complex to pyrolyze into small molecules during pyrolysis/GC/MS. ESI-FTICRMS gave no signal for toluene-insolubles probably because the fraction was insoluble in the methanol or acetonitrile, water and formic acid mixture used as solvent to the ESI source. LDMS was able to generate ions from each of the fractions. Fractionation of complex samples is necessary to separate smaller molecules to allow the use of higher laser fluences for the larger molecules and suppress the formation of ionized molecular clusters. The upper mass limit of the pitch was determined as between 5000 and 10,000 u. The pitch asphaltenes showed a peak of maximum intensity in the LDMS spectra at around m/z 400, in broad agreement with the estimate from SEC. The mass ranges of the toluene-insoluble fraction found by LDMS and SEC (400-10,000 u with maximum intensity around 2000 u by LDMS and 100-9320 u with maximum intensity around 740 u by SEC) are higher than those for the asphaltene fraction (200-4000 u with maximum intensity around 400 u by LDMS and 100-2680 u with maximum intensity around 286 u by SEC) and greater than values considered appropriate for petroleum asphaltenes (300-1200 u with maximum intensity near 700 u).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Analysis of Phenol and Alkylphenols in Brazilian Coal Tar

The main purpose of this work is the identification and quantification of phenolic compounds in coal tar samples from a ceramics factory in Cocal (SC), Brazil. The samples were subjected to preparative scale liquid chromatography, using Amberlyst A-27 ion-exchange resin as stationary phase. The fractions obtained were classified as “acids” and “BN” (bases and neutrals). The identification and q...

متن کامل

The Pentane- and Toluene-Soluble Fractions of a Petroleum Residue and three Coal Tars by Size Exclusion Chromatography and UV-Fluorescence Spectroscopy

The Pentaneand Toluene-Soluble Fractions of a Petroleum Residue and three Coal Tars by Size Exclusion Chromatography and UV-Fluorescence Spectroscopy — A petroleum atmospheric pressure distillate residue and three tars derived from different coals using different severities of thermal treatment were separated into seven fractions using column chromatography on silica and sequential elution by t...

متن کامل

Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix

A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...

متن کامل

Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry.

This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrom...

متن کامل

Improving the Yield and Quality of Tar during Co-pyrolysis of Coal and Cotton Stalk

Co-pyrolysis of Shenmu coal (SM) and cotton stalk (CS) at different blend ratios were carried out in a tubular furnace. The pyrolysis temperature was up to 600 °C at 5 °C/min and kept for 15 min. The results indicated that there was an interactive effect between SM and CS, which increased the tar yield. Moreover, the content of light components in co-pyrolysis tar from all CS/SM blend ratios wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 23 13  شماره 

صفحات  -

تاریخ انتشار 2009