Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography

نویسندگان

  • Sachi Kojima
  • Toshihiro Inoue
  • Takahiro Kawaji
  • Hidenobu Tanihara
چکیده

PURPOSE To determine the clinical features of tear fluid signs associated with filtration blebs via three-dimensional anterior segment optical coherence tomography (3D AS-OCT). METHODS In total, 152 eyes (130 patients) with glaucoma that underwent trabeculectomy with mitomycin C were evaluated retrospectively. We investigated tear fluid signs associated with filtration blebs, using 3D AS-OCT with custom software, and compared the findings of lower tear meniscus. We also analyzed postoperative intraocular pressure and the bleb parameters of filtration blebs between eyes with and without tear fluid signs. RESULTS We found tear fluid signs associated with filtration blebs in 45 (30%) of 152 eyes. The mean postoperative intraocular pressure of the eyes with the tear fluid sign in a filtration bleb was significantly lower than that in eyes without the tear fluid sign (P<0.001). Blebs with tear fluid signs have more frequent identifiable filtration openings, greater total height, increased fluid-filled cavity height, and less wall intensity compared with blebs without these signs. CONCLUSION We identified tear fluid signs in AS-OCT images on or along filtration blebs that depended on bleb morphology. The occurrence of these signs may be related to the presence of functional blebs, which may thereby control postoperative intraocular pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precise identification of filtration openings on the scleral flap by three-dimensional anterior segment optical coherence tomography.

PURPOSE To elucidate the potential of three-dimensional anterior segment optical coherence tomography (3D AS-OCT) for identifying filtration openings where aqueous humor flows from the sclera into the subconjunctival space. METHODS We used 3D AS-OCT and custom software to identify filtration openings, which were defined by pits and/or troughs in fluid-filled cavities in both horizontal and ve...

متن کامل

Anterior Segment Optical Coherence Tomography Imaging of Conjunctival Filtering Blebs after Glaucoma Surgery

Time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) are cross-sectional, noncontact, high-resolution diagnostic modalities for posterior and anterior segment (AS) imaging. The AS-OCT provides tomographic imaging of the cornea, iris, lens, and anterior chamber (AC) angle in several ophthalmic diseases. In glaucoma, AS-OCT is utilized to evaluate the morphology of AS stru...

متن کامل

Analysis of Bleb Morphology After Trabeculectomy with Anterior Segment Optical Coherence Tomography

TITLE: Analysis of bleb morphology after trabeculectomy with anterior segment optical coherence tomography. PURPOSE: To describe the use of Anterior segment optical coherence tomography (AS OCT ) in imaging of trabeculectomy bleb to find out the morphology and internal structure, and correlate its internal characteristics with the function of the bleb. METHODS: Observational case-series study.6...

متن کامل

Evaluation of Filtering Bleb Function after Trabeculectomy with Mitomycin C Using Biomicroscopy, Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy

OBJECTIVES To analyze and assess compatibility of trabeculectomy filtering bleb characteristics and appearances using biomicroscopy, anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). MATERIALS AND METHODS Twenty-eight eyes of 28 patients who underwent glaucoma filtering surgery with mitomycin C in our clinic between 2009 and 2013 were evaluated. Mo...

متن کامل

Dynamic changes in ocular Zernike aberrations and tear menisci measured with a wavefront sensor and an anterior segment OCT.

PURPOSE To measure dynamic change characteristics of spatial and temporal variations in the post-blink tear film of normal eyes. METHODS A wavefront sensor was used to measure dynamic changes in wavefront aberrations, up to the seventh order, for 10 seconds in a group of 33 normal young adults. Tear menisci were imaged with an anterior segment optical coherence tomography (AS-OCT) system and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014