Thesis Title : “ Evaluation of the Radiation Detection Properties of Synthetic

نویسندگان

  • Nicholas Ade
  • Trevor Derry
چکیده

Aimed at improving the accuracy of dose determination in radiation medicine, this thesis explores the radiation detection properties of synthetic diamond crystals of various types and investigates the possibility of developing a single probe with synthetic diamond as sensor for the dosimetry of various beam types under large as well as small-field conditions. The study was conducted on two HPHT (high-pressure, high-temperature) and eight CVD (chemical vapor deposited) synthesized diamonds of optical grade (OG) and detector grade (DG) qualities of various dimensions. Various non-destructive techniques were employed to characterize the electrical quality and defect levels present within each of the samples. Detector performances were evaluated using a prototype probe housing constructed of tissueequivalent materials. The probe has features, which allow diamond crystals to be exposed in different exposure orientations (‘edge-on’ and ‘flat-on’) for impinging radiation without having first to re-orient the diamond sensor within its body. All dosimetric measurements taken with the synthetic diamond probe were from exposures to low-energy mammography X-rays (25-32 kVp), and megavoltage therapy electron (7-14 MeV) and photon (Co γ-ray, 6 and 15 MV X-ray) beams. The most important findings emphasized in this thesis include: (1) The main cause of the response instability of the examined crystals necessitating the often cited daily primimg procedure was isolated and ascribed to the presence of ambient light which has the effect of emptying trapping centres present within the diamond sensors. The percentage changes in response between measurements in light and dark conditions conducted over a period of three successive weeks were 2.8±1.2, 25.2±6.3 and 63.0±0.3% for HPHT, DG and OG CVD diamond detectors, respectively. For measurements under light conditions alone using the tested detectors, the difference in response was > 5%, whereas in dark conditions the difference in response was < 3%. This signifies that once the diamond sensors are properly shielded from ambient light and their response stabilized, daily priming is not necessary;

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incremental Bayesian Segmentation for Intrusion Detection

This thesis describes an attempt to monitor patterns of system calls generated by a Unix host in order to detect potential intrusion attacks. Sequences of system calls generated by privileged processes are analyzed using incremental Bayesian segmentation in order to detect anomalous activity. Theoretical analysis of various aspects of the algorithm and empirical analysis of performance on synth...

متن کامل

Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

متن کامل

Evaluation of the Effect of Less Negatively Charged Amino Acid Substitution in Synthetic Tetramer Peptide S3 Derived from Horseshoe Crab Ambocyte on its Antibacterial Properties

Introduction: The study of the effects of synthetic peptides with antibacterial properties can provide more effective antibiotics. This study designed, expressed, and investigated the Sushi 3 tetramer peptide. Subsequently, it was compared in terms of changing antibacterial properties with another Sushi3 tetramer peptide the aspartic acid and proline amino acids of which were replaced with glyc...

متن کامل

Evaluation of the role of system matrix in SPECT images reconstructed by OSEM technique

  Introduction: Ordered subset expectation maximization (OSEM), is an effective iterative method for SPECT image reconstruction. The aim of this study is the evaluation of the role of system matrix in OSEM image reconstruction method using four different physical beam radiation models with three detection configurations. Methods: SPECT was done with an arc of 180 deg...

متن کامل

بررسی پایان نامه های فارغ التحصیلان دوره پزشکی عمومی در نیمه اول سال 1378 دانشگاه علوم پزشکی و خدمات بهداشتی درمانی ایران از نظر رعایت اصول علمی نگارش

  University is a suitable place for research because of enough facilities and active students. Each student should has enough knowledge in research field before his or her graduation. Submission of an appreciate thesis could be a beginning for advanced research, therefore we evaluated the methodological structure of submitted theses by medical students in Iran university of medical sciences in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015