Lung ultrasound for the evaluation of pulmonary congestion in outpatients: a comparison with clinical assessment, natriuretic peptides, and echocardiography.
نویسندگان
چکیده
OBJECTIVES The aim of this study was to define the performance of lung ultrasound (LUS) compared with clinical assessment, natriuretic peptides, and echocardiography, to evaluate decompensation in patients with systolic heart failure (HF) in an outpatient clinic. BACKGROUND Evaluation of pulmonary congestion in chronic HF is challenging. LUS has been recently proposed as a reliable tool for the semiquantification of extravascular lung water through assessment of B-lines. METHODS This was a cohort study of patients with moderate to severe systolic HF. Receiver-operating characteristic (ROC) analyses were performed to compare LUS with a previously validated clinical congestion score (CCS), amino-terminal portion of B-type natriuretic peptide (NT-proBNP), E/e' ratio, chest x-ray, and 6-min walk test. RESULTS Ninety-seven patients were enrolled. Decompensation was present in 57.7% of patients when estimated by CCS, 68% by LUS, 53.6% by NT-proBNP, and 65.3% by E/e' ≥15. The number of B-lines was correlated to NT-proBNP (r = 0.72; p < 0.0001), E/e' (r = 0.68; p < 0.0001), and CCS (r = 0.43; p < 0.0001). In ROC analyses, considering as reference for decompensation a combined method (E/e' ≥ 15 and/or NT-proBNP >1,000 pg/ml), LUS yielded a C-statistic of 0.89 (95% confidence interval: 0.82 to 0.96), providing the best accuracy with a cutoff ≥ 15 B-lines (sensitivity 85%, specificity 83%). A systematic approach using CCS, E/e', NT-proBNP, chest x-ray, and 6-min walk test in different combinations as reference for decompensation also corroborated this cutoff and found a similar accuracy for LUS. CONCLUSIONS In an HF outpatient clinic, B-lines were significantly correlated with more established parameters of decompensation. A B-line ≥15 cutoff could be considered for a quick and reliable assessment of decompensation in outpatients with HF.
منابع مشابه
Effective and Timely Evaluation of Pulmonary Congestion: Qualitative Comparison Between Lung Ultrasound and Thoracic Bioelectrical Impedance in Maintenance Hemodialysis Patients
The assessment of pulmonary congestion in maintenance hemodialysis (MHD) patients is challenging. Bioelectrical impedance analysis (BIA) can estimate body water compartments. Natriuretic peptides are markers of hemodynamic stress, neurohormonal activation and extracellular volume overload. Lung ultrasound (LUS) has been proposed for the non-invasive estimation of extravascular lung water throug...
متن کاملThe five-point Likert scale for dyspnea can properly assess the degree of pulmonary congestion and predict adverse events in heart failure outpatients
OBJECTIVES Proper assessment of dyspnea is important in patients with heart failure. Our aim was to evaluate the use of the 5-point Likert scale for dyspnea to assess the degree of pulmonary congestion and to determine the prognostic value of this scale for predicting adverse events in heart failure outpatients. METHODS We undertook a prospective study of outpatients with moderate to severe h...
متن کاملB-lines: to count or not to count?
We read with a great interest the paper by Miglioranza et al. (1), which sought to define the performance of lung ultrasound (LUS) compared with a clinical congestion score, natriuretic peptides, and echocardiography, to evaluate decompensation in patients with systolic heart failure (HF) in an outpatient clinic. This paper is a valuable effort to bridge the gap between echocardiography and tho...
متن کاملAssociation between B-lines detected during lung ultrasound and various factors in hemodialysis patients
Background: In recent years, the use of chest ultrasonography to detect lung water has received growing attention in clinical research. Estimation of the number of B-lines using lung ultrasound is now a standard method for the evaluation of pulmonary congestion. In the present study, we examined the relation between the number of B-lines and clinical parameters in hemodialysis patients. Methods...
متن کاملA Simplified Ultrasound Comet Tail Grading Scoring to Assess Pulmonary Congestion in Patients with Heart Failure
Ultrasound lung comets (ULCs) are a nonionizing bedside approach to assess extravascular lung water. We evaluated a protocol for grading ULC score to estimate pulmonary congestion in heart failure patients and investigated clinical and echocardiographic correlates of the ULC score. Ninety-three patients with congestive heart failure, admitted to the emergency department, underwent pulmonary ult...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 6 11 شماره
صفحات -
تاریخ انتشار 2013