Rapid and reagentless detection of microbial contamination within meat utilizing a smartphone-based biosensor
نویسندگان
چکیده
A smartphone-utilized biosensor was developed for detecting microbial spoilage on ground beef, without using antibodies, microbeads or any other reagents, towards a preliminary screening tool for microbial contamination on meat products, and potentially towards wound infection. Escherichia coli K12 solutions (10(1)-10(8) CFU/mL) were added to ground beef products to simulate microbial spoilage. An 880 nm near infrared LED was irradiated perpendicular to the surface of ground beef, and the scatter signals at various angles were evaluated utilizing the gyro sensor and the digital camera of a smartphone. The angle that maximized the Mie scatter varied by the E. coli concentration: 15° for 10(8) CFU/mL, 30° for 10(4) CFU/mL, and 45° for 10 CFU/mL, etc. SEM and fluorescence microscopy experiments revealed that the antigens and cell fragments from E. coli bonded preferably to the fat particles within meat, and the size and morphologies of such aggregates varied by the E. coli concentration.
منابع مشابه
An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction
Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...
متن کاملA Sensitive Novel Approach towards the Detection of 8-Hydroxyquinoline at Anionic Surfactant Modified Carbon Nanotube Based Biosensor: A Voltammetric Study
A rapid electrochemical technique was developed to determine 8-Hydroxyquinoline (8HQ). In the current study, the anionic surfactant Sodium lauryl sulfate (SLS) was immobilized on the multi-walled carbon nanotube (MWCNT) paste surface for the fabrication of electrode to detect 8HQ in phosphate buffer solution (PBS) of pH 7.0. The response of SLS modified carbon nanotube paste electrode (SLSMCNTP...
متن کاملReagentless detection of microorganisms by intrinsic fluorescence.
Quick and accurate detection of microbial contamination is accomplished by a unique combination of leading-edge technologies described in this and the accompanying paper. In this contribution, a hand-held prototype instrument is described which is capable of statistically sampling the environment for microbial contamination and determining cell viability. The technology is sensitive enough to d...
متن کاملLAMP assay for rapid diagnosis of cow DNA in goat milk and meat samples
Animal species detection is one of the crucial steps for consumer’s food analysis. In the present study we developed an in-house built loop-mediated isothermal amplification (LAMP) assay for rapid detection of adulterated cow DNA in goat milk/meat samples. The cow milk/tissue DNA in goat milk/meat samples were identified in the developed LAMP assay by either naked eye visualizing with SYBR Gree...
متن کاملModified Tin Oxide Based Bioelectrode for Reagentless Detection of Uric Acid
A reagentless uric acid biosensor has been realized using Copper implanted tin oxide thin film (Cu:SnO2) based matrix. The biosensing characteristics of implanted matrix have been studied using the electrochemical impedance spectroscopy and cyclic voltammetry. The prepared matrix (Cu:SnO2), because of the presence of Cu, possess redox properties so that the electron transfer from enzyme to the ...
متن کامل