Quantification of regional myocardial blood flow using 13N-ammonia and reoriented dynamic positron emission tomographic imaging.

نویسندگان

  • W G Kuhle
  • G Porenta
  • S C Huang
  • D Buxton
  • S S Gambhir
  • H Hansen
  • M E Phelps
  • H R Schelbert
چکیده

BACKGROUND Regional myocardial blood flow has been quantified using transaxial positron emission tomographic (PET) imaging and tracer kinetic modeling. However, the use of transaxial images limits the accuracy of regional partial volume corrections and the localization of the quantified regional flow values. The purpose of the present study was to overcome both problems by calculating regional flows from reoriented short-axis PET images. METHODS AND RESULTS Twelve experiments were performed in four dogs. 13N-ammonia was injected intravenously while microspheres were administered into the left atrium during baseline, hyperemic, and low-flow conditions. Serial transaxial frames were acquired with a 15-plane PET scanner and reoriented into short-axis frames. The arterial input function and eight regional myocardial tissue activity curves were derived from the reoriented frames. The arterial input functions were corrected for ammonia metabolites, and the myocardial tissue curves were corrected for spillover of activity, partial volume effects, and heterogeneities in the image's spatial resolution introduced during reorientation. Corrections for regional partial volume were based on estimates of the regional myocardial activity thickness derived from reoriented diastolic images of the heart. The myocardial 13N-ammonia kinetics were described with a two-pool compartmental model. Values of regional myocardial blood flow by PET correlated linearly with those by microspheres (slope, 0.94; y intercept, 0.06 ml/min/g; r = 0.93) over a wide range of flows. CONCLUSIONS Regional myocardial blood flow can be measured accurately and noninvasively from serially acquired and reoriented short-axis 13N-ammonia images, thus overcoming limitations inherent to the use of transaxially acquired images and permitting a more complete evaluation of regional blood flows throughout the left ventricular myocardium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of Regional Myocardial Blood Flow Using '3N-Ammonia and Reoriented Dynamic Positron Emission Tomographic Imaging

Background. Regional myocardial blood flow has been quantified using transaxial positron emission tomographic (PET) imaging and tracer kinetic modeling. However, the use of transaxial images limits the accuracy of regional partial volume corrections and the localization of the quantified regional flow values. The purpose of the present study was to overcome both problems by calculating regional...

متن کامل

Direct comparison of [13N]ammonia and [15O]water estimates of perfusion with quantification of regional myocardial blood flow by microspheres.

BACKGROUND Both [13N]ammonia and [15O]water have been used to quantify myocardial blood flow with positron emission tomography using appropriate tracer kinetic models. A direct comparison of the two tracers with radioactive microspheres has not been performed in the same experimental preparation. METHODS AND RESULTS The two tracers have been tested for myocardial blood flow quantification in ...

متن کامل

13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided in...

متن کامل

13N-ammonia myocardial blood flow and uptake: relation to functional outcome of asynergic regions after revascularization.

OBJECTIVES In this study we determined whether 13N-ammonia uptake measured late after injection provides additional insight into myocardial viability beyond its value as a myocardial blood flow tracer. BACKGROUND Myocardial accumulation of 13N-ammonia is dependent on both regional blood flow and metabolic trapping. METHODS Twenty-six patients with chronic coronary artery disease and left ve...

متن کامل

Regional blood flow, oxidative metabolism, and glucose utilization in patients with recent myocardial infarction.

BACKGROUND Metabolic imaging with positron emission tomography (PET) can detect tissue viability in clinical infarct regions. With appropriate tracer kinetic models and serial PET imaging, regional myocardial blood flow and rates of metabolism can now be quantified in patients with recent myocardial infarctions. METHODS AND RESULTS Serial PET imaging with [13N]ammonia, [11C]acetate, and 18F-d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 86 3  شماره 

صفحات  -

تاریخ انتشار 1992