ROC surface assessment of the ANB angle and Wits appraisal's diagnostic performance with a statistically derived 'gold standard': does normalizing measurements have any merit?
نویسندگان
چکیده
Objective To assess the ANB angle's and Wits appraisal's diagnostic performance using an extended version of Receiver Operating Curve (ROC) analysis, which renders ROC surfaces. These were calculated for both the conventional and normalized cephalometric tests (calculated by exchanging the patient's reference landmarks with those of the Procrustes superimposed sample mean shape).The required 'gold standard' was derived statistically, by applying generalized Procrustes superimposition (GPS) and principal component analysis (PCA) to the digitized landmarks, and ordering patients based upon their PC2 scores. Methods Digitized landmarks of 200 lateral cephalograms (107 males, mean age: 12.8 years, SD: 2.2, 93 females, mean age: 13.2 years, SD: 1.7) were subjected to GPS and PCA. Upon calculating the conventional and normalized ANB and Wits values, ROC surfaces were constructed by varying not just the cephalometric test's cut-off value within each ROC curve, but also the gold standard cut-off value over different ROC curves in 220 steps between -2 and 2 standard deviations along PC2. The volume under the resulting ROC surfaces (VUS) served as a measure of overall diagnostic performance. The statistical significance of the volume differences was determined using permutation tests (1000 rounds, with replacement). Results The diagnostic performance of the conventional ANB and Wits was remarkably similar for both Class I/II (81.1 and 80.75% VUS, respectively, P > 0.05). Normalizing the measurements improved all VUS highly significantly (91 and 87.2 per cent, respectively, P < 0.001). Conclusion The conventional ANB and Wits do not differ in their diagnostic performance. Normalizing the measurements does seem to have some merit.
منابع مشابه
Study between anb angle and wits appraisal in cone beam computed tomography (cbct)
OBJECTIVES To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. STUDY DESIGN Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry in...
متن کاملCo-relation between Anb Angle, Wits Value & Snp Plane Angle
ANB angle & Wits value are used to asses the Sagital pattern of the patient cephalometrically. The two variables are dependent on change in the Antero-posterior & vertical position of Point A. SNP plane angle determines the rotation change in position of Palatal plane with reference to SN plane. This rotational change might have an impact on the position of point A and thus the ANB angle and wi...
متن کاملAssessing the Correlation between Cephalometric Measurements In Patients with Class II Malocclusion
Background and purpose: Some measurements such as angles and planes drawn in lateral cephalometry have different relationships and correlation coefficients which help to distinguish different types of malocclusions. The aim of this study was to investigate the correlation between ANB, Wits, occlusal plane, and Y-axis cephalometric measurements in patients with class II malocclusion. Materials...
متن کاملComparison of different angular measurements to assess sagittal Jaw discrepancy in Jaipur population- A cephelometric study
Introduction: In orthodontic diagnosis and treatment planning an accurate evaluation of sagittal jaw relationship is important. To assess the antero-posterior jaw discrepancy between maxilla and mandible, numerous angular and linear measurements have been in corporate so as to reach correct diagnosis. So the purpose of this study is to compare ANB angle, Wits appraisal, Beta angle and W angle u...
متن کاملبررسی میزان همبستگی تعدادی از شاخصهای افقی اکسترا و اینتراکرانیال سفالومتری
Introduction: Intra-cranial references plans used in cephalometry analysis are not considered as stable points and therefore their validity is low however they are widely used. The purpose of conducting this study is to investigate correlation rate of a number of horizontal parameters of extra-cranial with common Horizontal analyses. Methods: In this descriptive and periodic study, lateral ce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 39 4 شماره
صفحات -
تاریخ انتشار 2017