Geometric feature-based multimodal image registration of contrast-enhanced cardiac CT with gated myocardial perfusion SPECT.
نویسندگان
چکیده
PURPOSE Cardiac computed tomography (CT) and single photon emission computed tomography (SPECT) provide clinically complementary information in the diagnosis of coronary artery disease (CAD). Fused anatomical and physiological data acquired sequentially on separate scanners can be coregistered to accurately diagnose CAD in specific coronary vessels. METHODS A fully automated registration method is presented utilizing geometric features from a reliable segmentation of gated myocardial perfusion SPECT (MPS) volumes, where regions of myocardium and blood pools are extracted and used as an anatomical mask to de-emphasize the inhomogeneities of intensity distribution caused by perfusion defects and physiological variations. A multiresolution approach is employed to represent coarse-to-fine details of both volumes. The extracted voxels from each level are aligned using a similarity measure with a piecewise constant image model and minimized using a gradient descent method. The authors then perform limited nonlinear registration of gated MPS to adjust for phase differences by automatic cardiac phase matching between CT and MPS. For phase matching, they incorporate nonlinear registration using thin-plate-spline-based warping. Rigid registration has been compared with manual alignment (n=45) on 20 stress/rest MPS and coronary CTA data sets acquired from two different sites and five stress CT perfusion data sets. Phase matching was also compared to expert visual assessment. RESULTS As compared with manual alignment obtained from two expert observers, the mean and standard deviation of absolute registration errors of the proposed method for MPS were 4.3 +/- 3.5, 3.6 +/- 2.6, and 3.6 +/- 2.1 mm for translation and 2.1 +/- 3.2 degrees, 0.3 +/- 0.8 degree, and 0.7 +/- 1.2 degrees for rotation at site A and 3.8 +/- 2.7, 4.0 +/- 2.9, and 2.2 +/- 1.8mm for translation and 1.1 +/- 2.0 degrees, 1.6 +/- 3.1 degrees, and 1.9 +/- 3.8 degrees for rotation at site B. The results for CT perfusion were 3.0 +/- 2.9, 3.5 +/- 2.4, and 2.8 +/- 1.0 mm for translation and 3.0 +/- 2.4 degrees, 0.6 +/- 0.9 degree, and 1.2 +/- 1.3 degrees for rotation. The registration error shows that the proposed method achieves registration accuracy of less than 1 voxel (6.4 x 6.4 x 6.4 mm) misalignment. The proposed method was robust for different initializations in the range from -80 to 70, -80 to 70, and -50 to 50 mm in the x-, y-, and z-axes, respectively. Validation results of finding best matching phase showed that best matching phases were not different by more than two phases, as visually determined. CONCLUSIONS The authors have developed a fast and fully automated method for registration of contrast cardiac CT with gated MPS which includes nonlinear cardiac phase matching and is capable of registering these modalities with accuracy <10 mm in 87% of the cases.
منابع مشابه
The prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease
Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملSimulation and patient studies of scatter correction in cardiac SPECT imaging
Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 36 12 شماره
صفحات -
تاریخ انتشار 2009