Unstable intertrochanteric fractures: how to prevent uncontrolled impaction and shortening of the femur.

نویسندگان

  • Miodrag Bogosavljević
  • Dragan Stokić
  • Zan Friscić
  • Branko M Ristić
چکیده

BACKGROUND/AIM Unstable intertrochanteric (IT) fractures, especially fractures with a reverse or transverse fracture line, have tendencies to make significant impaction on shortening of the femoral neck and lower extremity. The biomechanical complexity of the fracture, the type and the position of the implant are known to influence postoperative outcome. The aim of this study was to compare characteristics of two versions of dynamic hip implants in controlling the dynamization of unstable IT fractures of the femur. METHODS In the prospective study that included 1,115 patients with fractures of the proximal femur, 61 patients had IT fractures with a reverse or transverse fracture line. All the patients were treated surgically with the same implant in two versions: Dynamic Hip Screw - DHS-MB-S implant with a rigid part of standard length (40 mm) and DHS-MB-I implant, with a rigid part of the implant individualized for each patient depending on the transverse diameter of the proximal femur. The patients were under gradual radiographic and clinical control. Six months postoperatively we measured the length of the extremity and the degree of the medialization of the distal part of the femur. RESULTS All the fractures healed six months after the operation. Medialization and shortening of the extremity were significantly less in the group with fractures fixed by the DHS-MB-I implant, in which length of the rigid part of the implant was preoperatively measured individually for each patient. CONCLUSION In order to achieve a desired functional result, the control of dynamisation in unstable IT fractures is significant in the fixation of these fractures of the femur. We presented possible methods to realize it by the contact of the rigid part of our implant with medial cortex of the proximal fragment of the femur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does the PFNA™ nail limit impaction in unstable intertrochanteric femoral fracture? A 115 case-control series.

INTRODUCTION Femoral neck shortening after dynamic fixation of extra-capsular fracture may impair functional results, but is rarely assessed. The present study measured impaction in stable and unstable fractures (on the Ender classification) treated by PFNA™ nail. The objectives were: 1) to validate the Ender classification to assess fracture stability; 2) to determine whether neck shortening a...

متن کامل

Femoral shortening in intertrochanteric fractures. A comparison between the Medoff sliding plate and the compression hip screw.

We compared 54 patients treated by a Medoff sliding plate (MSP) with 60 stabilised by a compression hip screw (CHS) in a prospective, randomised study of the management of intertrochanteric femoral fractures. Four months after the operation femoral shortening was determined from radiographs of both femora. In unstable fractures the mean femoral shortening was 15 mm with the MSP and 11 mm with t...

متن کامل

How to Treat the Complex Unstable Intertrochanteric Fractures in Elderly Patients? DHS or Arthroplasty

Background:  Due to difficulty in obtaining anatomical reduction, management of the unstable intertrochanteric fractures in elderly osteoporotic patients is challenging. The purpose of this study is to compare the results of hip arthroplasty (total, hemi, or bipolar) with DHS in the elderly patients with unstable intertrochanteric fractures.   Methods:  We prospectively studied and followed-up ...

متن کامل

Peritrochanteric fractures: choosing your weapon!

INTERTROCHANTERIC FRACTURES Approximately 50% of intertrochanteric fractures are stable and have minimal or no posteromedial comminution. The remaining 50% are unstable and have posteromedial instability and little resistance to varus deformity.1,4,5 Older rigid devices led to cutout or penetration of the nail as the fracture impacted. In the late 1960s, sliding devices were developed to allow ...

متن کامل

Shortening of the Femoral Neck Following Peritrochanteric Fracture

Proximal femoral neck and peritrochanteric fractures are a devastating musculoskeletal injury resulting in markedly increased patient morbidity and mortality. As the annual incidence of fracture continues to increase, there is a recognized need to improve clinical outcomes following fixation, especially in peritrochanteric fractures. While many factors are associated with adverse patient outcom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vojnosanitetski pregled

دوره 68 5  شماره 

صفحات  -

تاریخ انتشار 2011