[Transobturator slings for female stress urinary incontinence].

نویسندگان

  • Ana Sousa
  • André Jesus
  • Maria Carvalho
  • Giselda Carvalho
  • João Marques
  • Francisco Falcão
  • Isabel Torgal
چکیده

INTRODUCTION Stress urinary incontinence affects about 20-40% of women. Treatment with transobturator mid-urethral slings is consensually accepted nowadays. The goal of this study was to evaluate the success rate and most frequent complications of surgical treatment with transobturator mid-urethral slings in stress urinary incontinence. MATERIAL AND METHODS This study evaluated 363 patients who underwent correction of stress urinary incontinence with a transobturator tape in Hospitais da Universidade de Coimbra between January 1st 2008 and July 1st 2010. RESULTS The mean age of patients was 56 [28-86]. In 13.5% of women, the correction of stress urinary incontinence was associated with other vaginal surgery. The majority of these women (95.3%) had urethral hypermobility. Only 0.8% of women suffered of perioperative complications, 5.2% of immediate postoperative complications and 15.7% of late postoperative complications. The global success rate was 93.7%. The success rate in patients with fixed urethra was lower (77.8%) comparing with the results of those with urethral hypermobility, being successful in 94.5% (p = 0.02). The success rate was similar in patients with or without vaginal surgeries. DISCUSSION Treatment with transobturator mid-urethral slings has high success rates and it became the first treatment chosen to stress urinary incontinence, even if they were treated with the technique outside-in (TOT®) or inside-out (TVT-O®). Both techniques were conceived to avoid passing through the retropubic space, decreasing the complicate matters number. CONCLUSIONS The cure rates for the transobturator surgical approach range between 80 and 95%. The cure rate increases when the mechanism responsible for the urinary incontinence is urethral hypermobility, although it is not modified when are performed other vaginal surgeries concomitantly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of female stress urinary incontinence using suburethral slings: comparative, retrospective, observational study of two surgical techniques.

OBJECTIVE The treatment of female stress urinary incontinence has undergone a revolution in recent years due the emergence on the market of suburethral slings. The aim of this study is to compare two surgical techniques for treating stress urinary incontinence: Monarc™ (transobturator suburethral sling) and MiniArc(®) (single-incision suburethral mini-sling). MATERIAL AND METHODS Comparative,...

متن کامل

Abdominovaginal Technique for Complete Removal of Transobturator Slings

Introduction and Objectives: Transobturator vaginal mesh is commonly used for the treatment of female stress urinary incontinence. Complications of transobturator mesh may include hip, groin, or leg pain that can occasionally be debilitating. Total removal of mesh may resolve or improve pain symptoms but can be a challenging or daunting procedure. In this video we present the technique of the c...

متن کامل

RetROpubic OR tRansObtuRatOR slings fOR tReatMent Of stRess uRinaRy incOntinence andRea lOpes salzedas tanuRi1, paulO cezaR feldneR jR2*, zsuzsanna i.K. jaRMy-di bella3,ROdRigO aquinO castRO4, MaRaiR gRaciO feRReiRa saRtORi5, ManOel jOãO batista

348 Rev Assoc Med Bras 2010; 56(3): 348-54 *Correspondence: Rua dos Otonis 601 Vila Clementino São Paulo-SP, Brazil CEP: 04025-001 Phone/Fax: (+55 11) 55739228 [email protected] AbstrACt Objective. To compare the results of retropubic and transobturator slings for surgical treatment of female stress urinary incontinence (SUI). MethOds. We randomized thirty patients with SUI, ten of whom unde...

متن کامل

Vaginal mesh extrusion associated with use of Mentor transobturator sling.

OBJECTIVES To describe my experience of vaginal mesh extrusion using the monofilament polypropylene transobturator sling, the Mentor ObTape. The Mentor ObTape was the first transobturator sling developed as an alternative to the retropubic commercially available suburethral slings for providing mid-urethral support as treatment of female stress urinary incontinence. METHODS Thirty patients un...

متن کامل

Transobturator Midurethral Slings versus Single-Incision Slings for Stress Incontinence in Overweight Patients

PURPOSE To compare transobturator midurethral sling (TOS) and single-incision sling procedures in terms of their effects on urinary incontinence and the quality of life in overweight (BMI ≥ 25-29.9 kg/m2) female patients using the International Consultation on Incontinence Questionnaire scoring form (ICIQ-SF) and Quality of Life of Persons with Urinary Incontinence scoring form (I-QOL). MATER...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica portuguesa

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2014