Forensic fluid dynamics and the Indian Spring (1991) cave collapse problem.
نویسنده
چکیده
Nof and Paldor (Safety Sci 2010;48:607-14) suggested that resonance in the air pockets in the Indian Spring cavern might have contributed to the 1991 collapse. Here, we extend the resonance theory to one pocket in the cavern and a very broad basin that serves as the other branch of the U-tube. Our methodology is to apply familiar fluid dynamics principles to the situation that occurred in the cave. We did so on the basis of our interviews with four of the five surviving cave divers. We dissected their testimonies to arrive at a physically plausible scenario determined on the basis of a fluid dynamics application to the natural flow in the cave, the flow induced by the compressed air released by the divers and the mudslide. We found that there was a temporary flow blocking during the collapse, but no total flow reversal within the cave.
منابع مشابه
Forensic Fluid Dynamics and the Indian Spring (1991) Cave Collapse Problem
Nof and Paldor (Safety Sci 2010;48:607–14) suggested that resonance in the air pockets in the Indian Spring cavern might have contributed to the 1991 collapse. Here, we extend the resonance theory to one pocket in the cavern and a very broad basin that serves as the other branch of the U-tube. Our methodology is to apply familiar fluid dynamics principles to the situation that occurred in the c...
متن کاملBubble-Induced Cave Collapse
Conventional wisdom among cave divers is that submerged caves in aquifers, such as in Florida or the Yucatan, are unstable due to their ever-growing size from limestone dissolution in water. Cave divers occasionally noted partial cave collapses occurring while they were in the cave, attributing this to their unintentional (and frowned upon) physical contact with the cave walls or the aforementi...
متن کاملEvaluation of the Droplet Collapsibility in Inhalation Drug Delivery through a 3D Computational Study
Background: Several multiphase flow analyses have been developed to predict the fate of particles used in inhalation drug delivery; however, the collapse of droplets during their passage through respiratory tract has not been investigated. Objective: To assess the probability of droplet collapse in the upper respiratory tract.Methods: A 3D model of mouth-to-second generation airway after the tr...
متن کاملComputational Fluid Dynamics Study of a Complete Coal Direct Chemical Looping Sub-Pilot Unit
The present Computational Fluid Dynamics (CFD) work deals with the modeling of complete coal direct chemical looping sub-pilot unit which use coal as fuel and ferric oxide supported on alumina as an oxygen carrier. The 2D CFD model of the complete arrangement incorporating both fuel and air reactors and their inter-connecting parts was solved using FLUENT. The CFD model wa...
متن کاملTransference of SH-Waves in Fluid Saturated Porous Medium Sandwiched Between Heterogeneous Half-Spaces
A mathematical model is considered to investigate the behavior of horizontally polarized shear waves (SH-waves) in fluid saturated porous medium sandwiched between heterogeneous half-spaces. Heterogeneity in the upper half-space is due to linear variation of elastic parameters, whereas quadratic variation has been considered for lower half-space. The method of separation of variables and Whitta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of forensic sciences
دوره 57 4 شماره
صفحات -
تاریخ انتشار 2012