Rigid Registration of Segmented Volumes in Frequency Domain Using Spherical Correlation
نویسندگان
چکیده
An algorithm for the rigid registration of binary volumes is described in this paper. Binary volumes result from a segmentation of ovarian ultrasound volumes. Rigid registration is preformed in frequency domain, where the rotation and translation can be calculated separately. The calculation of rotation is done using the amplitude spectrum and with the help of sphere correlation. The method was tested on 100 synthetic ultrasonic volume pairs. Registration accuracy was estimated by a ratio ρ that compares the intersection volume of the two registered volumes to the final volume. The average ratio ρ between registered volumes was 0.50 (std 0.09) when final result of registration was used. For comparison we tested transformation, used in synthetic volumes creation. The average ratio ρ was 0.53 (std. 0.08) in that case. Key-Words: image registration, rigid registration in frequency domain, spherical correlation
منابع مشابه
Influence of Noise on the Results of Rigid Registration of Segmented Ovarian Volumes Using Spherical Correlation in Frequency Domain
The influence of noise on the results of rigid registration of segmented ultrasound volumes is studied in this paper. Binary volumes result from a segmentation of ovarian ultrasound volumes. Rigid registration is preformed in frequency domain, where the rotation and translation can be calculated separately. The calculation of rotation is done using the amplitude spectrum and sphere correlation....
متن کاملOptimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps
Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...
متن کاملIntra-frame Motion Correction in Dynamic Radial Mri Using the Phase Correlation Method
performed to cover the complete k-space in several complementary portions, called segments, to reduce the effect of motion. Image-based registration can then be used for estimating motion from images reconstructed from these individual segments. However, its performance might be degraded because of undersampling artefacts as the segmentation gets higher. Recently, the phase correlation method (...
متن کاملNon-rigid registration methods assessment of 3D CT images for head-neck radiotherapy
Intensity Modulated Radiotherapy is a new technique enabling the sculpting of the 3D radiation dose. It enables to modulate the delivery of the dose inside the malignant areas and constrain the radiation plan for protecting important functional areas. It also raises the issues of adequacy and accuracy of the selection and delineation of the target volumes. The delineation in the patient image o...
متن کاملNewborn EEG Seizure Detection Based on Interspike Space Distribution in the Time-Frequency Domain
This paper presents a new time-frequency based EEG seizure detection method. This method uses the distribution of interspike intervals as a criterion for discriminating between seizure and nonseizure activities. To detect spikes in the EEG, the signal is mapped into the time-frequency domain. The high instantaneous energy of spikes is reflected as a localized energy in time-frequency domain. Hi...
متن کامل